Automated hollow fiber-protected dynamic liquid-phase microextraction of pesticides for gas chromatography - Mass spectrometric analysis

被引:96
作者
Hou, L [1 ]
Shen, G [1 ]
Lee, HK [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
关键词
liquid-phase microextraction; extraction methods; automation; pesticides;
D O I
10.1016/S0021-9673(02)01827-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dynamic liquid-phase microextraction (LPME) controlled by a programmable syringe pump was evaluated for extracting pesticides in water prior to GC-MS analysis. A conventional microsyringe with a 1.3-cm length of hollow fiber. attached to its needle was connected to a syringe pump to perform the extraction. The microsyringe was used as both the microextraction device as well as the sample introduction device for GC-MS analysis. The attached hollow fiber served as the "holder" and "protector" of 3 mul of organic solvent. The solvent was repeatedly withdrawn into and discharged from the hollow fiber by the syringe pump. Pesticides were extracted from 4-ml water samples into the organic solvent impregnated in the hollow fiber. The effects of organic solvents, plunger movement pattern, agitation and extraction time were investigated. Good repeatabilities of extraction performance were obtained, with the RSD values ranging from 3.0% (alachlor) to 9.8% (4-chlorophenol) for the 14 pesticides; most RSD values were under 5.0%. The method provided a 490-fold preconcentration of the target pesticides. The limits of detection were in the range of 0.01-5.1 mug/l (SIN=3) in the GC-MS selected ion monitoring mode. In addition, sample clean-up was achieved during LPME because of the selectivity of the hollow fiber, which prevented undesirable large molecules from being extracted. A slurry sample (mixture of 40 mg soil/ml of water) containing seven pesticides was extracted using this method which also gave good linearity and precision (most RSDs<7.0%, n=3). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 24 条
[1]   MICROEXTRACTION BY DEMIXING FOR THE DETERMINATION OF VOLATILE COMPOUNDS IN AQUEOUS-SOLUTIONS [J].
CACHO, J ;
FERREIRA, V ;
FERNANDEZ, P .
ANALYTICA CHIMICA ACTA, 1992, 264 (02) :311-317
[2]  
CHEREMISINOFF NP, 1994, TOXIC PROPERTIES PES
[3]   DETERMINATION OF PESTICIDES IN AQUEOUS SAMPLES BY SOLID-PHASE MICROEXTRACTION IN-LINE COUPLED TO GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
EISERT, R ;
LEVSEN, K .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (11) :1119-1130
[4]  
Guidotti M, 1996, HRC-J HIGH RES CHROM, V19, P469, DOI 10.1002/jhrc.1240190812
[5]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[6]   Solvent microextraction into a single drop [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2236-2240
[7]   Mass transfer characteristics of solvent extraction into a single drop at the tip of a syringe needle [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :235-239
[8]   Use of triethylenetetraminehexaacetic acid combined with field amplified sample injection in speciation analysis by capillary electrophoresis [J].
Liu, WP ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2666-2675
[9]   Quantitative analysis of pesticides by capillary column high performance liquid chromatography combined with solid-phase extraction [J].
Liu, WP ;
Lee, HK .
TALANTA, 1998, 45 (04) :631-639
[10]   Solid phase microextraction and headspace solid phase microextraction for the determination of polychlorinated biphenyls in water samples [J].
Llompart, M ;
Li, K ;
Fingas, M .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2510-2515