The role of multi-slice spiral CT angiography in patient management after endovascular therapy

被引:19
作者
Peloschek, P.
Sailer, J.
Loewe, C.
Schillinger, M.
Lammer, J.
机构
[1] Med Univ Vienna, AKH, Dept Radiol, A-1090 Vienna, Austria
[2] Med Univ Vienna, AKH, Dept Angiol, A-1090 Vienna, Austria
关键词
computed tomography; contrast media; PTA; stent; subclavian artery;
D O I
10.1007/s00270-004-0066-9
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Objectives: To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods: Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (+/- 27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results: All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion: MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated.
引用
收藏
页码:756 / 761
页数:6
相关论文
共 38 条
[1]
Timing of the hepatic arterial phase during contrast-enhanced computed tomography of the liver -: Assessment of normal values in 25 volunteers [J].
Bader, TR ;
Prokesch, RW ;
Grabenwöger, F .
INVESTIGATIVE RADIOLOGY, 2000, 35 (08) :486-492
[2]
Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Tran, HQ ;
Heiken, JP .
RADIOLOGY, 2000, 216 (03) :872-880
[3]
Evaluation of contrast densities in the diagnosis of carotid stenosis by CT angiography [J].
Claves, JL ;
Wise, SW ;
Hopper, KD ;
Tully, D ;
TenHave, TR ;
Weaver, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (02) :569-573
[4]
DELAGARZA O, 1992, ACTA ANAT, V145, P412
[5]
Spiral CT during selective accessory renal artery angiography: Assessment of vascular territory before aortic stent-grafting [J].
Dorffner, R ;
Thurnher, S ;
Prokesch, R ;
Youssefzadeh, S ;
Holzenbein, T ;
Lammer, J .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (02) :179-182
[6]
Angiographic prevalence and clinical predictors of left subclavian stenosis in patients undergoing diagnostic cardiac catheterization [J].
English, JL ;
Carell, ES ;
Guidera, SA ;
Tripp, HF .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (01) :8-11
[8]
Mathematical analysis of arterial enhancement and optimization of bolus geometry for CT angiography using the discrete Fourier transform [J].
Fleischmann, D ;
Hittmair, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) :474-484
[9]
Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography [J].
Fleischmann, D ;
Rubin, GD ;
Bankier, AA ;
Hittmair, K .
RADIOLOGY, 2000, 214 (02) :363-371
[10]
Peripheral pulmonary arteries: How far in the lung does multi-detector row spiral CT allow analysis? [J].
Ghaye, B ;
Szapiro, D ;
Mastora, I ;
Delannoy, V ;
Duhamel, A ;
Remy, J ;
Remy-Jardin, M .
RADIOLOGY, 2001, 219 (03) :629-636