3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent

被引:34
作者
Fink, C
Ley, S
Puderbach, M
Plathow, C
Bock, M
Kauczor, HU
机构
[1] German Canc Res Ctr, Dept Radiol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Med Phys Radiol, D-69120 Heidelberg, Germany
关键词
lung; magnetic resonance; contrast media; perfusion; pulmonary embolism;
D O I
10.1007/s00330-004-2282-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40degrees; voxel size: 1.3x2.5x4.0 mm(3); TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40degrees; voxel size: 0.8x1.0x1.6 mm(3)) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were per-formed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21 +/- 8 vs. 13 +/- 3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer.
引用
收藏
页码:1291 / 1296
页数:6
相关论文
共 23 条
[1]   Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigs [J].
Abolmaali, ND ;
Hietschold, V ;
Appold, S ;
Ebert, W ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2002, 12 (03) :692-697
[2]   Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilation-perfusion scintigraphy:: An intra-modality and inter-modality agreement study [J].
Amundsen, T ;
Torheim, G ;
Kvistad, KA ;
Waage, A ;
Bjermer, L ;
Nordlid, KK ;
Johnsen, H ;
Åsberg, A ;
Haraldseth, O .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) :386-394
[3]   MAGNETIC-RESONANCE-IMAGING DETECTION OF AN EXPERIMENTAL PULMONARY PERFUSION DEFICIT USING A MACROMOLECULAR CONTRAST AGENT - POLYLYSINE-GADOLINIUM-DTPA(40) [J].
BERTHEZENE, Y ;
VEXLER, V ;
PRICE, DC ;
WISNERDUPON, J ;
MOSELEY, ME ;
AICHER, KP ;
BRASCH, RC .
INVESTIGATIVE RADIOLOGY, 1992, 27 (05) :346-351
[4]  
Berthezène Y, 1999, J MAGN RESON IMAGING, V9, P61, DOI 10.1002/(SICI)1522-2586(199901)9:1<61::AID-JMRI8>3.0.CO
[5]  
2-Z
[6]   Incidence and distribution pattern of pulmonary saddle emboli: Diagnosis by electron beam tomography (EBT) [J].
Enzweiler, CNH ;
Lembcke, AE ;
Wiese, TH ;
Grohmann, A ;
Rogalla, P ;
Bollow, M ;
Kopka, L ;
Hamm, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07) :862-866
[7]   Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion -: Initial results [J].
Fink, C ;
Bock, M ;
Puderbach, M ;
Schmähl, A ;
Delorme, S .
INVESTIGATIVE RADIOLOGY, 2003, 38 (08) :482-488
[8]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[9]   Pulmonary perfusion: Qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH [J].
Hatabu, H ;
Gaa, J ;
Kim, D ;
Li, W ;
Prasad, PV ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :503-508
[10]   Evolution of pulmonary perfusion defects demonstrated with contrast-enhanced dynamic MR perfusion imaging [J].
Howarth, NR ;
Beziat, C ;
Berthezène, Y .
EUROPEAN RADIOLOGY, 1999, 9 (08) :1574-1576