Craniofacial reconstruction with computer-generated HTR patient-matched implants: Use in primary bony tumor excision

被引:61
作者
Eppley, BL [1 ]
机构
[1] Indiana Univ, Sch Med, Div Plast Surg, Indianapolis, IN USA
关键词
D O I
10.1097/00001665-200209000-00011
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of this clinical series is to report the effectiveness and safety of using computer-generated alloplastic hard tissue replacement (HTR) implants for the reconstruction of large defects of the cranio-orbital region when combined with simultaneous bone tumor excision. Seven patients who had large nonmalignant bony lesions of the anterior cranial vault and orbit underwent simultaneous bony excision and reconstruction with preoperatively fabricated custom alloplastic implants. Preoperatively, a 3D computed tomography (CT) scan was obtained from which an anatomical model was fabricated. On the anatomical model, the predicted amount of bone excision was performed. The defect in the model was then used to create an alloplastic (HTR polymer) implant for reconstruction and surgical placement. At the time of surgery, the implant was secured into position with either metal or resorbable plates and screws. In cases where the frontal sinus was in proximity to the implant, it was either cranialized and covered with a pericranial flap or obliterated with hydroxyapatite cement. All computer-generated implants required some modification intraoperatively due to a larger amount of bony excision than was preoperatively planned. This was accomplished by modifying the sterile back-up of the implant as an addition to the original implant or completing reconstruction of the bony defect with hydroxyapatite cement. All patients have healed uneventfully with a minimum of 1 year follow-up (average, 2.6 years). In all cases, excellent contours have been maintained and all patients have remained infection-free. In the management of large benign bony tumors of the cranio-orbital region, simultaneous reconstruction with custom implants fabricated from porous, hydrophilic HTR polymer can be preoperatively fabricated based on an estimate of the subsequent bony defect. The successful use of this approach depends on a favorable tissue quality of the recipient site, a generous preoperative estimate of the amount of bone that will be resected so that the implant is adequate, intraoperative techniques of expanding the implant reconstruction, and intraoperative methods to assure a partitioning of the implant from the frontal sinus.
引用
收藏
页码:650 / 657
页数:8
相关论文
共 15 条
[1]   STEREOLITHOGRAPHY IN ORAL AND MAXILLOFACIAL OPERATION PLANNING [J].
BILL, JS ;
REUTHER, JF ;
DITTMANN, W ;
KUBLER, N ;
MEIER, JL ;
PISTNER, H ;
WITTENBERG, G .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 24 (01) :98-103
[2]   Stereolithographic biomodelling in cranio-maxillofacial surgery: a prospective trial [J].
D'Urso, PS ;
Barker, TM ;
Earwaker, WJ ;
Bruce, LJ ;
Atkinson, RL ;
Lanigan, MW ;
Arvier, JF ;
Effeney, DJ .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (01) :30-37
[3]   EVALUATION OF HTR POLYMER AS A CRANIOMAXILLOFACIAL GRAFT MATERIAL [J].
EPPLEY, BL ;
SADOVE, AM ;
GERMAN, RZ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (06) :1085-1092
[4]   Computer-generated patient models for reconstruction of cranial and facial deformities [J].
Eppley, BL ;
Sadove, AM .
JOURNAL OF CRANIOFACIAL SURGERY, 1998, 9 (06) :548-556
[5]  
EPPLEY BL, IN PRESS J CRANIOFAC
[6]  
EPPLEY BL, IN PRESS PLAST RECON
[7]   Custom-made cast titanium implants produced with CAD/CAM for the reconstruction of cranium defects [J].
Heissler, E ;
Fischer, FS ;
Bolouri, S ;
Lehmann, T ;
Mathar, W ;
Gebhardt, A ;
Lanksch, W ;
Bier, J .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 27 (05) :334-338
[8]   Orbital reconstruction with individually copy-milled ceramic implants [J].
Hoffmann, J ;
Cornelius, CP ;
Groten, M ;
Pröbster, L ;
Pfannenberg, C ;
Schwenzer, N .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 101 (03) :604-612
[9]  
LAMBRECHT JT, 1990, CLEFT PALATE J, V27, P382, DOI 10.1597/1545-1569(1990)027<0382:ISMFFC>2.3.CO
[10]  
2