Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm

被引:43
作者
Felbinger, TW [1 ]
Reuter, DA [1 ]
Eltzschig, HK [1 ]
Moerstedt, K [1 ]
Goedje, O [1 ]
Goetz, AE [1 ]
机构
[1] Univ Munich, Grosshadern Med Ctr, D-80539 Munich, Germany
关键词
cardiac index; cardiac output; pulse contour analysis; thermodilution;
D O I
10.1016/S0952-8180(02)00363-X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To compare cardiac index (CI) measurement by arterial pulse contour analysis using two different algorithms (CIPC, CIPCnew) with pulmonary arterial thermodilution values (CIPA) so as to evaluate the difference between the conventional algorithm, CIPC, and a new algorithm, CIPCnew, that accounts for patients' individual aortic compliance. Design: Prospective clinical study Setting: Intensive care unit of a university hospital. Patients: 20 ASA physical status II and III patients following elective cardiac surgery. Measurements and Main Results: 360 parallel triplicate determinations of CI (CIPA, CIPC, CIPCnew) were performed within a 90-minute period during the immediate postoperative period. Prior to the start of the study period, CIPC as well as CIPCnew were calibrated by triplicate femoral arterial thermodilution measurements. Regression analysis of CIPA and CIPC, as well as CIPA and CIPCnew revealed r = 0.89, p < 0.001, and r = 0.93, p < 0.001, respectively. Bland-Altman analysis was used for determining the accuracy and precision of CIPC and CIPCnew compared with CIPA. The mean differences (m) and standard deviation (SD) between CIPA and CIPC, as well as CIPA and CIPCnew resulted in m = -0.312 L/min/m(2), SD = 0.456 L/min/m(2), and m = -0.140 L/min/m(2), SD = 0.328 L/min/m(2), respectively. Conclusion: Arterial pulse contour analysis measurement of CI using either algorithm correlates well with CI values derived by pulmonary arterial thermodilution. However, the algorithm introduced in this study proved to be a more accurate predictor of values as derived by pulmonary artery catheter. (C) 2002 by Elsevier Science Inc.
引用
收藏
页码:296 / 301
页数:6
相关论文
共 22 条
[1]  
Becker K, 1998, J CARDIOTHOR VASC AN, V12, P13
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Beat-to-beat stroke volume estimation from aortic pressure waveform in conscious rats: comparison of models [J].
Cerutti, C ;
Gustin, MP ;
Molino, P ;
Paultre, CZ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 281 (03) :H1148-H1155
[4]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[5]  
de Figueiredo LFP, 1999, J TRAUMA, V47, P288
[6]  
Frank O, 1930, Z BIOL-MUNICH, V90, P405
[7]   Continuous, less invasive, hemodynamic monitoring in intensive care after cardiac surgery [J].
Godje, O ;
Hoke, K ;
Lamm, P ;
Schmitz, C ;
Thiel, C ;
Weinert, M ;
Reichart, B .
THORACIC AND CARDIOVASCULAR SURGEON, 1998, 46 (04) :242-249
[8]   Less invasive, continuous hemodynamic monitoring during minimally invasive coronary surgery [J].
Gödje, O ;
Thiel, C ;
Lamm, P ;
Reichenspurner, H ;
Schmitz, C ;
Schütz, A ;
Reichart, B .
ANNALS OF THORACIC SURGERY, 1999, 68 (04) :1532-1536
[9]   Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution [J].
Goedje, O ;
Hoeke, K ;
Lichtwarck-Aschoff, M ;
Faltchauser, A ;
Lamm, P ;
Reichart, B .
CRITICAL CARE MEDICINE, 1999, 27 (11) :2407-2412
[10]   EVALUATION OF A NEW CONTINUOUS THERMODILUTION CARDIAC-OUTPUT MONITOR IN CRITICALLY ILL PATIENTS - A PROSPECTIVE CRITERION STANDARD STUDY [J].
HALLER, M ;
ZOLLNER, C ;
BRIEGEL, J ;
FORST, H .
CRITICAL CARE MEDICINE, 1995, 23 (05) :860-866