A bio-barcode assay for on-chip attomolar-sensitivity protein detection

被引:157
作者
Goluch, Edgar D.
Nam, Jwa-Min
Georganopoulou, Dimitra G.
Chiesl, Thomas N.
Shaikh, Kashan A.
Ryu, Kee S.
Barron, Annelise E.
Mirkin, Chad A.
Liu, Chang
机构
[1] Univ Illinois, Dept Bioengn, Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[2] Northwestern Univ, Dept Chem, Evanston, IL 60208 USA
[3] Northwestern Univ, Inst Nanotechnol, Evanston, IL 60208 USA
[4] Northwestern Univ, Dept Chem Engn, Evanston, IL 60208 USA
关键词
D O I
10.1039/b606294f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Functionalized nanoparticles hold great promise in realizing highly sensitive and selective biodetection. We report a single disposable chip which is capable of carrying out a multi-step process that employs nanoparticles-a bio-barcode assay (BCA) for single protein marker detection. To illustrate the capability of the system, we tested for the presence of prostate specific antigen (PSA) in buffer solution and goat serum. Detection was accomplished at PSA concentrations as low as 500 aM. This corresponds to only 300 copies of protein analytes using I mu L total sample volume. We established that the on-chip BCA for PSA detection offers four orders of magnitude higher sensitivity compared to commercially available ELISA-based PSA tests.
引用
收藏
页码:1293 / 1299
页数:7
相关论文
共 35 条
  • [1] Poly-N-hydroxyethylacrylamide as a novel, adsorbed coating for protein separation by capillary electrophoresis
    Albarghouthi, MN
    Stein, TM
    Barron, AE
    [J]. ELECTROPHORESIS, 2003, 24 (7-8) : 1166 - 1175
  • [2] Black MH, 2000, CLIN CANCER RES, V6, P467
  • [3] BRADEN ER, 2001, ELECTROPHORESIS, V22, P334
  • [4] MEASUREMENT OF PROSTATE-SPECIFIC ANTIGEN IN SERUM AS A SCREENING-TEST FOR PROSTATE-CANCER
    CATALONA, WJ
    SMITH, DS
    RATLIFF, TL
    DODDS, KM
    COPLEN, DE
    YUAN, JJJ
    PETROS, JA
    ANDRIOLE, GL
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (17) : 1156 - 1161
  • [5] Poly(acrylamide-co-alkylacrylamides) for electrophoretic DNA purification in microchannels
    Chiesl, TN
    Shi, W
    Barron, AE
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (03) : 772 - 779
  • [6] Covalent attachment of synthetic DNA to self-assembled monolayer films
    Chrisey, LA
    Lee, GU
    OFerrall, CE
    [J]. NUCLEIC ACIDS RESEARCH, 1996, 24 (15) : 3031 - 3039
  • [7] Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    Duffy, DC
    McDonald, JC
    Schueller, OJA
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 4974 - 4984
  • [8] Fernández-Sánchez C, 2004, ELECTROCHEM COMMUN, V6, P138, DOI [10.1016/j.elecom.2003.11.002, 10.1016/j.elecom.11.002]
  • [9] An answer in the palm of your hand:: Microfluidics for analytical applications
    Fintschenko, Y
    Choi, WY
    Cummings, EB
    Fréchet, JMJ
    Fruetel, JA
    Hilder, EF
    Mair, DA
    Shepodd, TJ
    Svec, F
    [J]. MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS, 2003, 4982 : 196 - 207
  • [10] An integrated microfabricated cell sorter
    Fu, AY
    Chou, HP
    Spence, C
    Arnold, FH
    Quake, SR
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (11) : 2451 - 2457