Evaluation of a new rigid carbon-castor oil polyurethane composite as an electrode material

被引:80
作者
Mendes, RK
Claro-Neto, S
Cavalheiro, ETG
机构
[1] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
[2] Univ Sao Paulo, Inst Quim Sao Carlos, Dept Quim & Fis Mol, BR-13560970 Sao Carlos, SP, Brazil
关键词
composite electrode material; graphite; polyurethane; ferricyanide; catechol; hydroquinone;
D O I
10.1016/S0039-9140(02)00122-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polyurethane resin derived from castor oil was used to prepare a graphite composite intented to be applied in voltammetry. The best graphite/resin content in the composite was evaluated using cyclic voltammetry. The useful potential window was investigated in different electrolytes with pH ranging from 1 to 13, with good results in relation to the glassy carbon electrode. Response of this new electrode material to ferricyanide, hydroquinone, catechol and cadmium(II) ions was investigated in cyclic voltammetry and/or differential pulse voltammetry. The composite showed to be also useful in flow procedures. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:909 / 917
页数:9
相关论文
共 21 条
[1]   CARBON PASTE ELECTRODES [J].
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1958, 30 (09) :1576-1576
[2]   A PVC-graphite composite electrode for electroanalytical use. Preparation and some applications [J].
Albertus, F ;
Llerena, A ;
Alpizar, J ;
Cerda, V ;
Luque, M ;
Rios, A ;
Valcarcel, M .
ANALYTICA CHIMICA ACTA, 1997, 355 (01) :23-32
[3]  
[Anonymous], Z ELECTROCHEM
[4]   Development of a carbon composite electrode made from polyethylene and graphite powder modified with copper(I) oxide [J].
Cataldi, TRI ;
Centonze, D .
ANALYTICA CHIMICA ACTA, 1996, 326 (1-3) :107-115
[5]   New materials for electrochemical sensing .1. Rigid conducting composites [J].
Cespedes, F ;
MartinezFabregas, E ;
Alegret, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) :296-304
[6]   DEVELOPMENT OF GRAPHITE-POLY(TETRAFLUOROETHYLENE) COMPOSITE ELECTRODES - VOLTAMMETRIC DETERMINATION OF THE HERBICIDES THIRAM AND DISULFIRAM [J].
FERNANDEZ, C ;
REVIEJO, AJ ;
PINGARRON, JM .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :192-199
[7]  
GUM G, 1994, ANAL CHIM ACTA, V294, P261
[8]  
Haddadi-Asl V, 1998, IRAN POLYM J, V7, P185
[9]   CARBON-POLYMER COMPOSITE ELECTRODES FOR REDOX CELLS [J].
HADDADIASL, V ;
KAZACOS, M ;
SKYLLAS-KAZACOS, M .
JOURNAL OF APPLIED POLYMER SCIENCE, 1995, 57 (12) :1455-1463
[10]  
Jin JY, 2000, ELECTROANAL, V12, P610, DOI 10.1002/(SICI)1521-4109(200005)12:8<610::AID-ELAN610>3.3.CO