Synthesis and application of XAD-2/Me-BTAP resin for on-line solid phase extraction and determination of trace metals in biological samples by FAAS

被引:23
作者
Azevedo Lemos, Valfredo [1 ]
Teixeira David, Graciete [1 ]
Santos, Luana Novaes [1 ]
机构
[1] Univ Estadual Sudoeste Bahia, Dept Quim & Exatas, BR-45200000 Jequie, BA, Brazil
关键词
Me-BTAP; synthesis; metal; amberlite XAD-2; on-line;
D O I
10.1590/S0103-50532006000400010
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new XAD-2/Me-BTAP resin has been developed and applied in an on-line system for the preconcentration followed by metal determination by FAAS. The reagent used in the resin synthesis was 2-[2'-(6-methyl-benzothiazolylazo)]-4-aminophenol (Me-BTAP), a compound produced by first time for the application described in this work. The reagent and resin were characterized and the sorbent was used as packing for the minicolumn in an on-line system preconcentration system for cobalt, copper and nickel determination. The enrichment factors calculated were 19 (Co), 12 (Cu) and 12 (Ni), for 60 s preconcentration time, and 30 (Co), 30 (Cu) and 24 (Ni), if used 180 s preconcentration time. The proposed procedure allowed the determination of cobalt, copper and nickel with limits of detection 0.34, 0.87 and 0.81 mu g L-1, respectively, when used preconcentration periods of 180 s. The accuracy of the developed procedure was evaluated by the analysis of certified reference materials. The method was applied to the analysis of food samples (black tea and rice flour).
引用
收藏
页码:697 / 704
页数:8
相关论文
共 41 条
[1]   Use of Amberlite XAD-2 loaded with 1-(2-pyridylazo)-2-naphthol as a preconcentration system for river water prior to determination of Cu2+, Cd2+ and Pb2+ by flame atomic absorption spectroscopy [J].
Bermejo-Barrera, P ;
Nancy, MA ;
Cristina, DL ;
Adela, BB .
MICROCHIMICA ACTA, 2003, 142 (1-2) :101-108
[2]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[3]   Synthesis and application of a functionalized resin for flow injection/F AAS copper determination in waters [J].
Cassella, RJ ;
Magalhaes, OIB ;
Couto, MT ;
Lima, ELS ;
Neves, MAFS ;
Coutinho, FMB .
TALANTA, 2005, 67 (01) :121-128
[4]   Flow injection determination of cobalt after its sorption onto polyurethane foam loaded with 2-(2-thiazolylazo)-p-cresol (TAC) [J].
Cassella, RJ ;
Salim, VA ;
Jesuíno, LS ;
Santelli, RE ;
Ferreira, SLC ;
de Carvalho, MS .
TALANTA, 2001, 54 (01) :61-67
[5]   Solid-phase organic synthesis of sensing sorbent materials for copper and lead recovery [J].
Castillo, M ;
Pina-Luis, G ;
Díaz-García, ME ;
Rivero, IA .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (3A) :412-417
[6]   Determination of trace metals in fuel alcohol by FAAS using Nb2O5-SiO2 as sorbent material in a flow injection on-line preconcentration system [J].
da Silva, EL ;
Budziak, D ;
Carasek, E .
ANALYTICAL LETTERS, 2004, 37 (09) :1909-1924
[7]   Field sampling system for determination of cadmium and nickel in fresh water by flame atomic absorption spectrometry [J].
dos Santos, WNL ;
dos Santos, CM ;
Ferreira, SLC .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (04) :727-732
[8]  
DOUTAN M, 2000, SEP SCI TECHNOL, V35, P2083
[9]   Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system [J].
Enríquez-Domínguez, MF ;
Yebra-Biurrun, MC ;
Bermejo-Barrera, MP .
ANALYST, 1998, 123 (01) :105-108
[10]  
Fang Z., 1993, FLOW INJECTION SEPAR