Flow injection determination of cobalt after its sorption onto polyurethane foam loaded with 2-(2-thiazolylazo)-p-cresol (TAC)

被引:56
作者
Cassella, RJ
Salim, VA
Jesuíno, LS
Santelli, RE [1 ]
Ferreira, SLC
de Carvalho, MS
机构
[1] Univ Fed Fluminense, Dept Geoquim, BR-24020007 Niteroi, RJ, Brazil
[2] CEFETEQ RJ, BR-20270021 Rio De Janeiro, Brazil
[3] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[4] CNEN, Inst Engn Nucl, Rio De Janeiro, Brazil
关键词
polyurethane foam; cobalt; solid phase extraction; flow injection analysis;
D O I
10.1016/S0039-9140(00)00626-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports the development of a new methodology for determination of cobalt in water samples by using a flow injection system with loaded PUF as solid phase to preconcentrate analytes. Procedure is based on on-line retention of Co(III) ions (generated in alkaline medium by Co(II) oxidation) in a minicolumn packed with a polyether type polyurethane foam loaded with TAC (2-(2-thiazolylazo)-p-cresol) and elution with 2 mol l(-1) HCl directly to the flame atomic absorption spectrometer nebulizer. Several chemical and flow variables that could affect the performance of this system were investigated as well as the possible interferents. For 2 min of preconcentration time (10.0 mi of sample volume) the system achieved a detection limit 3.2 mug l(-1) , a R.S.D. 5% at 20 mug l(-1) and an analytical throughput 24 h(-1). Whereas: for 3 min of preconcentration time (15.0 ml of sample volume) a detection limit 2.4 mug l(-1), a R.S.D. under 8% at 10 mug l(-1) and a sampling frequency 17 h(-1) were reported. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 17 条
[1]   POLYURETHANE-PYRIDYLAZONAPHTHOL FOAMS IN PRECONCENTRATION AND SEPARATION OF TRACE-ELEMENTS [J].
BRAUN, T ;
FARAG, AB ;
MALONEY, MP .
ANALYTICA CHIMICA ACTA, 1977, 93 (01) :191-201
[2]   SPECTROPHOTOMETRIC DETERMINATION OF TRACES OF COBALT IN WATER AFTER PRECONCENTRATION ON REAGENT-LOADED POLYURETHANE FOAMS [J].
BRAUN, T ;
ABBAS, MN .
ANALYTICA CHIMICA ACTA, 1980, 119 (01) :113-119
[3]   REVERSED PHASE FOAM CHROMATOGRAPHY - SEPARATION OF IRON FROM COPPER, COBALT AND NICKEL IN TRI-N-BUTYL PHOSPHATE-HYDROCHLORIC ACID SYSTEM [J].
BRAUN, T ;
BAKOS, L ;
SZABO, Z .
ANALYTICA CHIMICA ACTA, 1973, 66 (01) :57-66
[4]   PLASTICIZED OPEN-CELL POLYURETHANE FOAM AS A UNIVERSAL MATRIX FOR ORGANIC REAGENTS IN TRACE-ELEMENT PRECONCENTRATION .1. COLLECTION OF SILVER TRACES ON DITHIZONE FOAM [J].
BRAUN, T ;
FARAG, AB .
ANALYTICA CHIMICA ACTA, 1974, 69 (01) :85-96
[5]   PLASTICIZED OPEN-CELL POLYURETHANE FOAM AS A UNIVERSAL MATRIX FOR ORGANIC REAGENTS IN TRACE-ELEMENT PRECONCENTRATION .2. COLLECTION OF MERCURY TRACES ON DITHIZONE AND DIETHYLDITHIOCARBAMATE FOAMS [J].
BRAUN, T ;
FARAG, AB .
ANALYTICA CHIMICA ACTA, 1974, 71 (01) :133-140
[6]   REVERSED-PHASE FOAM CHROMATOGRAPHY - SEPARATION OF PALLADIUM, BISMUTH AND NICKEL IN TRIBUTYL PHOSPHATE THIOUREA PERCHLORIC ACID SYSTEM [J].
BRAUN, T ;
FARAG, AB .
ANALYTICA CHIMICA ACTA, 1972, 61 (02) :265-&
[7]  
Braun T., 1985, POLYURETHANE FOAM SO
[8]   Selectivity enhancement in spectrophotometry: on-line interference suppression using polyurethane foam minicolumn for aluminum determination with Methyl Thymol Blue [J].
Cassella, RJ ;
Santelli, RE ;
Branco, AG ;
Lemos, VA ;
Ferreira, SLC ;
de Carvalho, MS .
ANALYST, 1999, 124 (05) :805-808
[9]   On-line preconcentration system for flame atomic absorption spectrometry using unloaded polyurethane foam: determination of zinc in waters and biological materials [J].
Cassella, RJ ;
Bitencourt, DT ;
Branco, AG ;
Ferreira, SLC ;
de Jesus, DS ;
de Carvalho, MS ;
Santelli, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1749-1753
[10]   Retention of carbaryl by polyether type polyurethane foam: a critical study [J].
Cassella, RJ ;
Garrigues, S ;
Santelli, RE ;
de la Guardia, M .
ANALYST, 2000, 125 (02) :257-261