Flow injection determination of cobalt after its sorption onto polyurethane foam loaded with 2-(2-thiazolylazo)-p-cresol (TAC)

被引:56
作者
Cassella, RJ
Salim, VA
Jesuíno, LS
Santelli, RE [1 ]
Ferreira, SLC
de Carvalho, MS
机构
[1] Univ Fed Fluminense, Dept Geoquim, BR-24020007 Niteroi, RJ, Brazil
[2] CEFETEQ RJ, BR-20270021 Rio De Janeiro, Brazil
[3] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[4] CNEN, Inst Engn Nucl, Rio De Janeiro, Brazil
关键词
polyurethane foam; cobalt; solid phase extraction; flow injection analysis;
D O I
10.1016/S0039-9140(00)00626-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports the development of a new methodology for determination of cobalt in water samples by using a flow injection system with loaded PUF as solid phase to preconcentrate analytes. Procedure is based on on-line retention of Co(III) ions (generated in alkaline medium by Co(II) oxidation) in a minicolumn packed with a polyether type polyurethane foam loaded with TAC (2-(2-thiazolylazo)-p-cresol) and elution with 2 mol l(-1) HCl directly to the flame atomic absorption spectrometer nebulizer. Several chemical and flow variables that could affect the performance of this system were investigated as well as the possible interferents. For 2 min of preconcentration time (10.0 mi of sample volume) the system achieved a detection limit 3.2 mug l(-1) , a R.S.D. 5% at 20 mug l(-1) and an analytical throughput 24 h(-1). Whereas: for 3 min of preconcentration time (15.0 ml of sample volume) a detection limit 2.4 mug l(-1), a R.S.D. under 8% at 10 mug l(-1) and a sampling frequency 17 h(-1) were reported. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 17 条
[11]   Spectrophotometric determination of carbaryl by on-line elution after its preconcentration onto polyurethane foam [J].
Cassella, RJ ;
Garrigues, S ;
Santelli, RE ;
de la Guardia, M .
TALANTA, 2000, 52 (04) :717-725
[12]   Polyurethane foam as a sorbent for continuous flow analysis: Preconcentration and spectrophotometric determination of zinc in biological materials [J].
de Jesus, DS ;
Casella, RJ ;
Ferreira, SLC ;
Costa, ACS ;
de Carvalho, MS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :263-269
[13]  
Fang Z., 1993, FLOW INJECTION SEPAR
[14]   Separation and preconcentration of cobalt after sorption onto amberlite XAD-2 loaded with 2-(2-thiazolylazo)-p-cresol [J].
Ferreira, SLC ;
de Brito, CF .
ANALYTICAL SCIENCES, 1999, 15 (02) :189-191
[15]   An on-line solid phase extraction system using polyurethane foam for the spectrophotometric determination of nickel in silicates and alloys [J].
Ferreira, SLC ;
de Jesus, DS ;
Cassella, RJ ;
Costa, ACS ;
de Carvalho, MS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :287-292
[16]   SELECTIVE SEPARATION OF NICKEL(II) BY DIMETHYLGLYOXIME-TREATED POLYURETHANE FOAM [J].
LEE, DW ;
HALMANN, M .
ANALYTICAL CHEMISTRY, 1976, 48 (14) :2214-2218
[17]  
Miller J. C., 1993, STAT ANAL CHEM