Relationship between blood flow, thrombus, and neointima in stents

被引:44
作者
Richter, GM
Palmaz, JC
Noeldge, G
Tio, F
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Pathol, San Antonio, TX 78284 USA
[2] Univ Heidelberg, Dept Diagnost Radiol, Heidelberg, Germany
关键词
blood; flow dynamics; intimal hyperplasia; stents and prostheses; thrombosis;
D O I
10.1016/S1051-0443(99)70090-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To establish a relationship between flow, acute thrombus formation, and late intimal hyperplasia in arterial stents. MATERIALS AND METHODS: To compare short-term stent patency in the canine femoral artery with normal flow to that in the opposite femoral artery with restricted flow, 24 dogs were subdivided in four groups: groups 1 (no intravenous heparin) and 2 (intravenous heparin) had unilateral flow restriction by surgically created stenosis, downstream of a Palmaz stent. Group 3 (no intravenous heparin) and 4 (intravenous heparin) had sham surgical exposure of the corresponding arterial segment, without flow restriction. Thrombocyte activity over the stent segment was evaluated for 3 hours after stent placement with nuclear scanning, after administration of indium-111-labeled platelets. To evaluate longterm stent patency in relationship to arterial flow, 14 additional dogs were subjected to long-term observation. Matched, symmetrically implanted femoral stents with normal and restricted flow, were explanted at 1, 12, and 24 weeks for histologic analysis and comparative measurement of neointimal thickness. Angiographic studies were performed before and after nuclear scanning in the short-term study group and before explant in the long-term animal group. RESULTS: In the short-term, groups 2 and 4 showed neither increased platelet uptake nor angiographically demonstrable thrombus. Group 1 had increased platelet uptake and occlusive or suboclusive angiographic thrombus. Group 3 had increased platelet uptake and angiographic thrombus in one instance. In the long-term, stents with flow restriction had significantly greater neointimal formation in comparison with unrestricted stents. Histologic studies suggested that the stent neointima resulted from progressive replacement of stent thrombus. CONCLUSION: Regardless of flow condition, intravenous heparinization is necessary to prevent thrombus formation in the stent lumen. Within the experimental parameters of this study, low flow and absent heparinization consistently lead to stent thrombosis. Stent implantation under low flow is associated with increased neointima formation. It is not known whether this is preventable by antithrombotic medication.
引用
收藏
页码:598 / 604
页数:7
相关论文
共 23 条
[1]   CONFORMATION OF HUMAN PLASMA-PROTEINS AT POLYMER SURFACES - THE EFFECTIVENESS OF SURFACE HEPARINIZATION [J].
BARBUCCI, R ;
MAGNANI, A .
BIOMATERIALS, 1994, 15 (12) :955-962
[2]   ROLE OF BLOOD-FLOW IN PLATELET ADHESION, FIBRIN DEPOSITION, AND FORMATION OF MURAL THROMBI [J].
BAUMGARTNER, HR .
MICROVASCULAR RESEARCH, 1973, 5 (02) :167-179
[3]   PLATELET-ADHESION, RELEASE AND AGGREGATION IN FLOWING BLOOD - EFFECTS OF SURFACE PROPERTIES AND PLATELET-FUNCTION [J].
BAUMGARTNER, HR ;
MUGGLI, R ;
TSCHOPP, TB ;
TURITTO, VT .
THROMBOSIS AND HAEMOSTASIS, 1976, 35 (01) :124-138
[4]   Management of restenosis after coronary intervention [J].
Dangas, G ;
Fuster, V .
AMERICAN HEART JOURNAL, 1996, 132 (02) :428-436
[5]  
ELGUE G, 1993, THROMB HAEMOSTASIS, V70, P289
[6]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[7]   LATE ANGIOGRAPHIC FOLLOW-UP AFTER PALMAZ-SCHATZ STENT IMPLANTATION [J].
FOLEY, JB ;
WHITE, J ;
TEEFY, P ;
ALMOND, DG ;
BROWN, RIG ;
PENN, IM .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (01) :76-77
[8]   Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries [J].
Hardhammar, PA ;
vanBeusekom, HMM ;
Emanuelsson, HU ;
Hofma, SH ;
Albertsson, PA ;
Verdouw, PD ;
Boersma, E ;
Serruys, PW ;
vanderGiessen, WJ .
CIRCULATION, 1996, 93 (03) :423-430
[9]   Three-year follow-up after implantation of metallic coronary-artery stents [J].
Kimura, T ;
Yokoi, H ;
Nakagawa, Y ;
Tamura, T ;
Kaburagi, S ;
Sawada, Y ;
Sato, Y ;
Yokoi, H ;
Hamasaki, N ;
Nosaka, H ;
Nobuyoshi, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) :561-566
[10]   GENERALIZED-MODEL OF RESTENOSIS AFTER CONVENTIONAL BALLOON ANGIOPLASTY, STENTING AND DIRECTIONAL ATHERECTOMY [J].
KUNTZ, RE ;
GIBSON, CM ;
NOBUYOSHI, M ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :15-25