Determination of trace-level haloacetic acids in drinking water by ion chromatography-inductively coupled plasma mass spectrometry

被引:34
作者
Liu, YJ
Mou, SF
Chen, DY
机构
[1] Chinese Acad Sci, Ecoenvironm Sci Res Ctr, Beijing 100085, Peoples R China
[2] Agilent Technol Co Ltd, Beijing 100085, Peoples R China
关键词
water analysis; haloacetic acids; halogenated compounds; acetic acids;
D O I
10.1016/j.chroma.2003.12.069
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method for the determination of nine haloacetic acids (HAAs) with ion chromatography (1C) coupled to inductively coupled plasma mass spectrometry (ICP-MS) was developed. With the very hydrophilic anion-exchange column and steep gradient of sodium hydroxide, the nine HAAs could be well separated in 15 min. After suppression with an ASRS suppressor that was introduced in between IC and ICP-MS, the background was much decreased, the interference caused by sodium ion present in eluent was removed, and the sensitivities of HAAs were greatly improved. The chlorinated and brominated HAAs could be detected as (CIO)-C-35 and Br-79 without interference of the matrix due to the elemental selective ICP-MS. The detection limits for mono-, di-, trichloroacetic acids were between 15.6 and 23.6 mug/l. For the other six bromine-containing HAAs, the detection limits were between 0.34 and 0.99 mug/l. With the pretreatment of OnGuard Ag cartridge to remove high concentration of chloride in sample, the developed method could be applied to the determination of HAAs in many drinking water matrices. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 28 条
[1]  
[Anonymous], REV WHO GUID DRINK W
[2]   Isotope dilution analysis of bromate in drinking water matrixes by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Brockhoff, CA .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :722-726
[3]  
CREED JT, 1997, 3218 EPA ENV MON SYS
[4]  
*DION, 2001, 031688 DION
[5]   Detection of nine chlorinated and brominated haloacetic acids at part-per-trillion levels using ESI-FAIMS-MS [J].
Ells, B ;
Barnett, DA ;
Purves, RW ;
Guevremont, R .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4555-4559
[6]   Detection of chlorinated and brominated byproducts of drinking water disinfection using electrospray ionization-high-field asymmetric waveform ion mobility spectrometry-mass spectrometry [J].
Ells, B ;
Barnett, DA ;
Froese, K ;
Purves, RW ;
Hrudey, S ;
Guevremont, R .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4747-4752
[7]  
*EPA, 1995, EPA600R95131 ENV MON
[8]  
Hashimoto S, 1998, HRC-J HIGH RES CHROM, V21, P55, DOI 10.1002/(SICI)1521-4168(19980101)21:1&lt
[9]  
55::AID-JHRC55&gt
[10]  
3.0.CO