Bromate is a disinfection byproduct in drinking water which is formed during the ozonation of source water containing bromide. This paper describes the analysis af bromate via ion chromatography-inductively coupled plasma mass spectrometry. The separation of bromate from interferences such as bromide and brominated haloacetic acids is achieved using a PA-100 column in combination with a 5 mM HNO3 + 25 mM NH4NO3 mobile phase. Polyatomic ions are observed on masses 79 and 81 in a synthetic phosphate matrix and its ozonated drinking waters. These polyatomic ions have been tentatively identified as PO3+ and H2PO3+. These polyatomic ions do not interfere with the detection of bromate because phosphate elutes prior to bromate. A polyatomic ion is observed on mass 81 in a synthetic sulfate matrix and in ozonated drinking waters. This polyatomic ion has been tentatively identified as HSO3+ and does not interfere with the detection of bromate because sulfate elutes after bromate. Isotope dilution analysis produces a relative standard deviation (RSD) of similar to 5% for both enriched isotopic additions at sample concentrations of 10 ng/g. The RSD associated with the direct analysis of bromate is 3.2% at sample concentrations of 10 ng/g. The bromate concentrations determined in ozonated drinking waters via isotope dilution analysis are within 10% of the concentrations determined via direct analysis for sample concentrations above 2 ng/g. The detection limit for the direct analysis of bromate via IC-ICPMS is 0.3 ng/g.
引用
收藏
页码:722 / 726
页数:5
相关论文
共 28 条
[1]   Trace analysis of bromate and bromide with ion chromatography on coated reversed phase materials [J].
Bohme, U ;
Schmidt, W ;
Dietrich, PG ;
Matschi, A ;
Sacher, F ;
Brauch, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (06) :629-634
[2]   Electrospray ion chromatography tandem mass spectrometry of bromate at sub-ppb levels in water [J].
Charles, L ;
Pepin, D ;
Casetta, B .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2554-2558
[3]  
CREED J, 1997, 45 ASMS C MASS SPECT
[4]   Determination of bromate in the presence of brominated haloacetic acids by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Magnuson, ML ;
Brockhoff, CA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (07) :2059-2063
[5]   Bromide/bromate speciation by NTI-IDMS and ICP-MS coupled with ion exchange chromatography [J].
Diemer, J ;
Heumann, KG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01) :74-79
[6]  
*EPA, 1997, 600R98118 EPA
[7]  
EPA Environmental Protection Agency, 1993, EPA600R93100
[8]   STABLE ISOTOPE-DILUTION ANALYSIS OF HYDROLOGIC SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GARBARINO, JR ;
TAYLOR, HE .
ANALYTICAL CHEMISTRY, 1987, 59 (11) :1568-1575
[9]   TRACE ANALYSES FOR WASTEWATERS [J].
GLASER, JA ;
FOERST, DL ;
MCKEE, GD ;
QUAVE, SA ;
BUDDE, WL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (12) :1426-1435
[10]   THE MEASUREMENT OF VERY-LOW LEVEL BROMATE ION [J].
GORDON, G ;
BUBNIS, B .
OZONE-SCIENCE & ENGINEERING, 1995, 17 (05) :551-559