Feasibility of using a video-based motion analysis system for measuring thumb kinematics

被引:62
作者
Kuo, LC
Su, FC [1 ]
Chiu, HY
Yu, CY
机构
[1] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Sect Plast Surg, Dept Surg, Tainan 701, Taiwan
[3] Natl Cheng Kung Univ, Dept Radiol, Tainan 701, Taiwan
关键词
thumb; kinematics; motion analysis; fluoroscopy;
D O I
10.1016/S0021-9290(02)00083-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
While several different methods have been used to measure hand kinematics, fluoroscopy is generally considered to be the most accurate. Recently, video-based motion analysis has been developed for the measurement of joint kinematics. This method is versatile, easy to use, and can measure motions dynamically. Surface markers are most commonly used in the video-based motion systems. However, whether the surface markers placed on the thumb accurately represent the true kinematics of the underlying bony segment is questionable. In this study, the feasibility of surface markers to represent thumb kinematics was investigated by fluoroscopy. Both the positions of surface markers and bony landmarks were simultaneous recorded and then digitized. The Ra-2 values comparing the angular changes of the thumb interphalangeal, metacarpal and carpometacarpal joints derived using the surface markers or bony landmarks were 0.9986, 0.9730 and 0.9186 in the flexion/extension plane respectively, 0.8837, 0.9697 and 0.8775 in the abduction/adduction plane; and 0.9884, 0.9643 and 0.9431 in the opposition plane. The ranges, mean and standard deviation of the absolute differences between calculated angles of different marker sets were also compared. These data revealed that the similarities of the two different marker techniques throughout the motion cycle were high. The differences between the two methods were also within clinically allowable range of +/- 5degrees. It is concluded that the application of the video-based motion analysis system with surface markers to thumb kinematics is warranted. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1499 / 1506
页数:8
相关论文
共 18 条
[1]  
AN KN, 1990, HAND CLIN, V6, P393
[2]   AN IMAGE-PROCESSING METHOD FOR SPINE KINEMATICS - PRELIMINARY STUDIES [J].
BREEN, A ;
ALLEN, R ;
MORRIS, A .
CLINICAL BIOMECHANICS, 1988, 3 (01) :5-10
[3]   The motion analysis system and the maximal area of fingertip motion - A preliminary report [J].
Chiu, HY ;
Su, FC .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1996, 21B (05) :604-608
[4]   COORDINATION OF INDEX FINGER MOVEMENTS [J].
DARLING, WG ;
COLE, KJ ;
MILLER, GF .
JOURNAL OF BIOMECHANICS, 1994, 27 (04) :479-491
[5]   The motion path of the digits [J].
Gupta, A ;
Rash, GS ;
Somia, NN ;
Wachowiak, MP ;
Jones, J ;
Desoky, A .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (06) :1038-1042
[6]  
HAHN P, 1995, J HAND SURG B, V20, P695
[7]   FINGER JOINT FORCE MINIMIZATION IN PIANISTS USING OPTIMIZATION TECHNIQUES [J].
HARDING, DC ;
BRANDT, KD ;
HILLBERRY, BM .
JOURNAL OF BIOMECHANICS, 1993, 26 (12) :1403-1412
[8]   KINEMATICS OF THE TRAPEZIOMETACARPAL JOINT AFTER SECTIONING OF LIGAMENTS [J].
IMAEDA, T ;
NIEBUR, G ;
AN, KN ;
COONEY, WP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (02) :205-210
[9]   Feasibility of using a magnetic tracking device for measuring carpal kinematics [J].
Ishikawa, J ;
Niebur, GL ;
Uchiyama, S ;
Linscheid, RL ;
Minami, A ;
Kaneda, K ;
An, KN .
JOURNAL OF BIOMECHANICS, 1997, 30 (11-12) :1183-1186
[10]   REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860