Beating heart catheter-based edge-to-edge mitral valve procedure in a porcine model - Efficacy and healing response

被引:80
作者
Fann, JI
St Goar, FG
Komtebedde, J
Oz, MC
Block, PC
Foster, E
Butany, J
Feldman, T
Burdon, TA
机构
[1] Stanford Univ, Med Ctr, Dept Cardiothorac Surg, Stanford, CA 94305 USA
[2] Cardiovasc Inst, Mountain View, CA USA
[3] Evalve Inc, Redwood City, CA USA
[4] Columbia Univ, New York, NY USA
[5] Emory Univ, Atlanta, GA 30322 USA
[6] Univ Calif San Francisco, San Francisco, CA 94143 USA
[7] Univ Toronto, Toronto, ON, Canada
[8] Evanston NW Healthcare, Evanston, IL USA
关键词
mitral valve; catheters; surgery; echocardiography;
D O I
10.1161/01.CIR.0000139855.12616.15
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Surgical edge-to-edge repair has been used in the treatment of mitral regurgitation. We evaluated the ability of a catheter-delivered clip (Evalve, Inc) to achieve edge-to-edge mitral valve approximation without cardiopulmonary bypass and the healing response of this technique. Methods and Results - Twenty-one pigs underwent general anesthesia and left thoracotomy. A 10F flexible delivery catheter with a clip was placed into the left atrium. With echocardiographic and fluoroscopic guidance, the clip grasped and approximated the mid portion of the anterior and posterior leaflets. After a double orifice had been confirmed, the clip was detached and the catheter withdrawn. All animals survived and had successful clip placement. Three animals were euthanized at 4 weeks, 9 at 12 weeks, 1 at 17 weeks, 7 at 24 weeks, and 1 at 52 weeks. The clip was well positioned, with leaflet approximation in all animals except 1, in which the clip separated from the posterior leaflet at 4 weeks without affecting valve function. The clip was modified and implanted in 4 pigs; all were intact at 12 to 24 weeks. Scanning electron microscopy showed clip encapsulation with complete endothelialization. Mitral stenosis and thromboembolism did not develop. Two animals developed endocarditis ( 1 at 12 weeks and 1 at 17 weeks). Progressive healing occurred in all other animals. Conclusions - Edge-to-edge mitral valve approximation can be successfully and reliably achieved with a catheter-delivered clip without cardiopulmonary bypass, resulting in durable healing. The success of this device supports the development of a percutaneous catheter- based system for mitral valve repair.
引用
收藏
页码:988 / 993
页数:6
相关论文
共 17 条
[1]   The double-orifice technique in mitral valve repair: A simple solution for complex problems [J].
Alfieri, O ;
Maisano, F ;
De Bonis, M ;
Stefano, PL ;
Torracca, L ;
Oppizzi, M ;
La Canna, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (04) :674-681
[2]   Novel suture device for beating-heart mitral leaflet approximation [J].
Alfieri, O ;
Elefteriades, JA ;
Chapolini, RJ ;
Steckel, R ;
Allen, WJ ;
Reed, SW ;
Schreck, S .
ANNALS OF THORACIC SURGERY, 2002, 74 (05) :1488-1493
[3]  
Cowart RP, 1999, CONTEMP TOP LAB ANIM, V38, P67
[4]   Beating-heart mitral valve surgery: Preliminary model and methodology [J].
Downing, SW ;
Herzog, WA ;
McLaughlin, JS ;
Gilbert, TP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (06) :1141-1146
[5]   Mitral valve surgery in patients with extensive calcification of the mitral annulus [J].
Feindel, CM ;
Tufail, Z ;
David, TE ;
Ivanov, J ;
Armstrong, S .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) :777-782
[6]   The edge-to-edge technique as a trick to rescue an imperfect mitral valve repair [J].
Gatti, G ;
Cardu, G ;
Trane, R ;
Pugliese, P .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (05) :817-820
[7]   Edge-to-edge mitral valve repair: The Columbia presbyterian experience [J].
Kherani, AR ;
Cheema, FH ;
Casher, J ;
Fal, JM ;
Mutrie, CJ ;
Chen, JM ;
Morgan, JA ;
Vigilance, DW ;
Garrido, MJ ;
Smith, CR ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 2004, 78 (01) :73-76
[8]   TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN PIGLETS [J].
LOCK, JE ;
BASS, JL ;
LUND, G ;
RYSAVY, JA ;
LUCAS, RV .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (06) :826-829
[9]   The double-orifice technique for mitral valve reconstruction: predictors of postoperative outcome [J].
Lorusso, R ;
Borghetti, V ;
Totaro, P ;
Parrinello, G ;
Coletti, G ;
Minzioni, G .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (03) :583-589
[10]   The double-orifice technique as a standardized approach to treat mitral regurgitation due to severe myxomatous disease: surgical technique [J].
Maisano, F ;
Schreuder, JJ ;
Oppizzi, R ;
Fiorani, B ;
Fino, C ;
Alfieri, O .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (03) :201-205