Beating-heart mitral valve surgery: Preliminary model and methodology

被引:28
作者
Downing, SW
Herzog, WA
McLaughlin, JS
Gilbert, TP
机构
[1] Univ Maryland, Sch Med, Div Cardiac Anesthesiol, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Dept Med, Baltimore, MD 21201 USA
关键词
D O I
10.1067/mtc.2002.121680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: It is our hypothesis that image-guided mitral valve repair can be performed on the beating heart without cardiopulmonary bypass. As a first phase, we tested the feasibility of suturing the anterior and posterior mitral valve leaflets under image guidance. Methods: In a water bath model, imaging approaches and suturing techniques were developed. Then, in 6 pigs, the left atrium was cannulated with a custom-made 15-mm valved port through a left thoracotomy. Atrial pressure was elevated by shunting of arterial blood to minimize air induction. A multiplane transesophageal echocardiographic probe was evaluated in the intraesophageal and epicardial positions. With a commercial endoscopic suturing device, sutures were placed through the anterior and posterior mitral leaflets under echocardiographic guidance. The animals were killed, and suture accuracy was evaluated by measuring the distance from the intended target areas on the anterior and posterior mitral leaflets. Air induction was monitored by echocardiography and graded as minimal to severe. Results: There were no cases of hemodynamic instability or significant arrhythmia. The most effective imaging plane was a short-axis view that used the transesophageal echocardiographic probe epicardially at the heart base. Air induction was minimal in 2 animals, mild in 3, and moderate in 1. Sutures were successfully placed 9 of 12 times (mean error 0.8 ± 0.5 cm). Conclusions: With these methods, off-pump, image-guided suturing of the beating-heart mitral valve was possible. This model may be a useful starting point for developing off-pump mitral valve repair procedures.
引用
收藏
页码:1141 / 1146
页数:6
相关论文
共 28 条
[1]  
Alfieri O, 1999, J CARDIAC SURG, V14, P468
[2]   Intracardiac surgery - A new method - Preliminary report [J].
Allen, DS ;
Graham, EA .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1922, 79 :1028-1030
[3]   The role of transesophageal echocardiography during port-access minimally invasive cardiac surgery: A new challenge for the echocardiographer [J].
Applebaum, RM ;
Colvin, SB ;
Galloway, AC ;
Ribakove, GH ;
Grossi, EA ;
Tunick, PA ;
Kronzon, I .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (06) :595-602
[4]   Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience [J].
Chan, KC ;
Godman, MJ ;
Walsh, K ;
Wilson, N ;
Redington, A ;
Gibbs, JL .
HEART, 1999, 82 (03) :300-306
[5]   Minimally invasive cardiac valve surgery improves patient satisfaction while reducing costs of cardiac valve replacement and repair [J].
Cohn, LH ;
Adams, DH ;
Couper, GS ;
Bichell, DP ;
Rosborough, DM ;
Sears, SP ;
Aranki, SF .
ANNALS OF SURGERY, 1997, 226 (04) :421-426
[6]   Minimally invasive valve operations [J].
Cosgrove, DM ;
Sabik, JF ;
Navia, JL .
ANNALS OF THORACIC SURGERY, 1998, 65 (06) :1535-1538
[7]  
CUTLER EC, 1923, BOSTON MED SURG J, V188, P1022
[8]  
DeMoor M, 1996, S AFR MED J, V86, pC97
[9]   RELEASE OF VASOACTIVE SUBSTANCES DURING CARDIOPULMONARY BYPASS [J].
DOWNING, SW ;
EDMUNDS, LH .
ANNALS OF THORACIC SURGERY, 1992, 54 (06) :1236-1243
[10]  
Edmunds L H Jr, 1995, Adv Card Surg, V6, P131