MCE-electrochemical detection for following interactions of ssDNA and dsDNA with methylene blue

被引:13
作者
Castano-Alvarez, Mario [1 ]
Fernandez-la-Villa, Ana [1 ]
Teresa Fernandez-Abedul, Maria [1 ]
Costa-Garcia, Agustin [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Asturias, Spain
关键词
DNA intercalators; Electrochemical detection; Gold end-channel detector; MCE; Topas; MICROCHIP CAPILLARY-ELECTROPHORESIS; AMPEROMETRIC DETECTION; DNA BIOSENSOR; SEPARATION; CHIPS; FABRICATION; TECHNOLOGY; GENOSENSOR; ELECTRODE; DOPAMINE;
D O I
10.1002/elps.200800711
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The interaction between the organic dye, methylene blue and DNA has been studied by MCE with electrochemical detection. Interaction produces two different signals, one corresponding to free methylene blue and other, for the complex methylene blue-DNA. The hybridization between a ssDNA and a complementary sequence, specific to the severe acute respiratory syndrome virus, has been performed and studied in a thermoplastic olefin polymer of amorphous structure CE-microchip with an end-channel gold wire detector. Moreover, studies with a longer dsDNA, an expression vector involved in the transitory or stable expression in mammals cells, pFLAG-CMV4, has also been performed.
引用
收藏
页码:1943 / 1948
页数:6
相关论文
共 30 条
[1]   Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements [J].
Abad-Villar, EM ;
Tanyanyiwa, J ;
Fernández-Abedul, MT ;
Costa-García, A ;
Hauser, PC .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1282-1288
[2]   Amperometric detector designs for capillary electrophoresis microchips [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (02) :291-299
[3]   Poly(methylmethacrylate) and Topas capillary electrophoresis microchip performance with electrochemical detection [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
ELECTROPHORESIS, 2005, 26 (16) :3160-3168
[4]   Electroactive intercalators for DNA analysis on microchip electrophoresis [J].
Castano-Alvarez, Mario ;
Teresa Fernandez-Abedul, M. ;
Costa-Garcia, Agustin .
ELECTROPHORESIS, 2007, 28 (24) :4679-4689
[5]   Separation of catecholamines and dopamine-derived DNA adduct using a microfluidic device with electrochemical detection [J].
Dawoud, A. A. ;
Kawaguchi, T. ;
Markushin, Y. ;
Porter, M. D. ;
Jankowiak, R. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 120 (01) :42-50
[6]   Capillary electrophoresis chips with a sheath-flow supported electrochemical detection system [J].
Ertl, P ;
Emrich, CA ;
Singhal, P ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3749-3755
[7]   Microchip capillary gel electrophoresis with electrochemical detection for the analysis of known SNPs [J].
Hebert, NE ;
Brazill, SA .
LAB ON A CHIP, 2003, 3 (04) :241-247
[8]   Enzymatic genosensor on streptavidin-modified screen-printed carbon electrodes [J].
Hernández-Santos, D ;
Díaz-González, M ;
González-García, MB ;
Costa-García, A .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :6887-6893
[9]   Electrochemical genosensor for the detection of interaction between methylene blue and DNA [J].
Kara, P ;
Kerman, K ;
Ozkan, D ;
Meric, B ;
Erdem, A ;
Ozkan, Z ;
Ozsoz, M .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (09) :705-709
[10]   Single-base mismatch detection based on charge transduction through DNA [J].
Kelley, SO ;
Boon, EM ;
Barton, JK ;
Jackson, NM ;
Hill, MG .
NUCLEIC ACIDS RESEARCH, 1999, 27 (24) :4830-4837