Poly(methylmethacrylate) and Topas capillary electrophoresis microchip performance with electrochemical detection

被引:48
作者
Castaño-Alvarez, M [1 ]
Fernández-Abedul, MT [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Asturias, Spain
关键词
capillary electrophoresis microchip; electrochemical detection; miniaturization; poly(methylmethacrylate); Pt end-channel detector; thermoplastic olefin polymer of amorphous structure;
D O I
10.1002/elps.200500148
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A capillary electrophoresis (CE) microchip made of a new and promising polymeric material: Topas (thermoplastic olefin polymer of amorphous structure), a cyclic olefin copolymer with high chemical resistance, has been tested for the first time with analytical purposes, employing an electrochemical detection. A simple end-channel platinum amperometric detector has been designed, checked, and optimized in a poly(methylmethacrylate) (PMMA) CE microchip. The end-channel design is based on a platinum wire manually aligned at the exit of the separation channel. This is a simple and durable detection in which the working electrode is not pretreated. H2O2 was employed as model analyte to study the performance of the PMMA microchip and the detector. Factors influencing migration and detection processes were examined and optimized. Separation of H2O2 and L-ascorbic acid (AsA) was developed in order to evaluate the efficiency of microchips using different buffer systems. This detection has been checked for the first time with a microchip made of Topas, obtaining a good linear relationship for mixtures of H2O2 and AsA in different buffers.
引用
收藏
页码:3160 / 3168
页数:9
相关论文
共 57 条
[1]   Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements [J].
Abad-Villar, EM ;
Tanyanyiwa, J ;
Fernández-Abedul, MT ;
Costa-García, A ;
Hauser, PC .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1282-1288
[2]  
ASHMEAD J, 2002, Patent No. 0229397
[3]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[4]   A chip-based electrophoresis system with electrochemical detection and hydrodynamic injection [J].
Backofen, U ;
Matysik, FM ;
Lunte, CE .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4054-4059
[5]   Polyelectrolyte-modified short microchannel for cation separation [J].
Bai, XX ;
Roussel, C ;
Jensen, H ;
Girault, HH .
ELECTROPHORESIS, 2004, 25 (06) :931-935
[6]   Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device [J].
Baldwin, RP ;
Roussel, TJ ;
Crain, MM ;
Bathlagunda, V ;
Jackson, DJ ;
Gullapalli, J ;
Conklin, JA ;
Pai, R ;
Naber, JF ;
Walsh, KM ;
Keynton, RS .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3690-3697
[7]   Amperometric PMMA-microchip with integrated gold working electrode for enzyme assays [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) :303-310
[8]   Miniaturized capillary electrophoresis system with a carbon nanotube microelectrode for rapid separation and detection of thiols [J].
Chen, G ;
Zhang, LY ;
Wang, J .
TALANTA, 2004, 64 (04) :1018-1023
[9]   Electrophoresis microchip fabricated by a direct-printing process with end-channel amperometric detection [J].
Coltro, WKT ;
da Silva, JAF ;
da Silva, HDT ;
Richter, EM ;
Furlan, R ;
Angnes, L ;
do Lago, CL ;
Mazo, LH ;
Carrilho, E .
ELECTROPHORESIS, 2004, 25 (21-22) :3832-3839
[10]   Microchip injection and separation anomalies due to pressure effects [J].
Crabtree, HJ ;
Cheong, ECS ;
Tilroe, DA ;
Backhouse, CJ .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4079-4086