Dual lifetime referenced optical sensor membrane for the determination of copper(II) ions

被引:83
作者
Mayr, T
Klimant, I
Wolfbeis, OS
Werner, T [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosci, D-93040 Regensburg, Germany
[2] Graz Univ Technol, Inst Analyt Chem, A-8110 Graz, Austria
关键词
dual lifetime referencing; DLR; copper(II); optical sensor; chemical imaging;
D O I
10.1016/S0003-2670(02)00234-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensor membrane has been developed for the determination of copper(II) ions that displays excellent performance due to internal referencing of luminescence intensities. The applied sensing scheme (dual lifetime referencing) makes use of the indicator lucifer yellow (LY) and an inert reference luminophore (a ruthenium complex entrapped in polyacrylonitrile beads). Both are contained in a hydrogel matrix. The copper-dependent fluorescence intensity change of LY can be converted in either a phase shift or time dependent parameter. The sensing membrane is capable of determining copper(II) with an outstanding high selectivity over a dynamic range between 1 and 1000 muM in neutral or weekly acidic conditions. The advantages of the referencing method over intensity based measurements was demonstrated by the measurement of turbid solutions. The scheme was also applied to two-dimensional measurements in the time domain. Sensor integrated microtiterplates were imaged with a CCD camera gated with square pulses in the microsecond range. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 24 条
[11]   Fluorescent imaging of pH with optical sensors using time domain dual lifetime referencing [J].
Liebsch, G ;
Klimant, I ;
Krause, C ;
Wolfbeis, OS .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4354-4363
[12]  
Liebsch G, 1999, ADV MATER, V11, P1296, DOI 10.1002/(SICI)1521-4095(199910)11:15<1296::AID-ADMA1296>3.0.CO
[13]  
2-B
[14]   MECHANISM OF QUENCHING OF EMISSION OF SUBSTITUTED POLYPYRIDINERUTHENIUM(II) COMPLEXES BY IRON(III), CHROMIUM(III), AND EUROPIUM(III) IONS [J].
LIN, CT ;
BOTTCHER, W ;
CHOU, M ;
CREUTZ, C ;
SUTIN, N .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1976, 98 (21) :6536-6544
[15]  
Malçik N, 2000, QUIM ANAL, V19, P94
[16]   Highly selective optical sensing of copper (II) ions based on fluorescence quenching of immobilised Lucifer Yellow [J].
Mayr, T ;
Werner, T .
ANALYST, 2002, 127 (02) :248-252
[17]  
Merian E., 1991, Metals and their Compounds in the Environment. Occurrence Analysis and Biological Relevance
[18]  
Muller T, 1999, Eur J Med Res, V4, P293
[19]   Optical sensors for determination of heavy metal ions [J].
Oehme, I ;
Wolfbeis, OS .
MIKROCHIMICA ACTA, 1997, 126 (3-4) :177-192
[20]   FIBEROPTIC SENSORS FOR PH AND CARBON-DIOXIDE USING A SELF-REFERENCING DYE [J].
PARKER, JW ;
LAKSIN, O ;
YU, C ;
LAU, ML ;
KLIMA, S ;
FISHER, R ;
SCOTT, I ;
ATWATER, BW .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2329-2334