Implementation and performance of an optical motion tracking system for high resolution brain PET imaging

被引:92
作者
Lopresti, BJ
Russo, A
Jones, WF
Fisher, T
Crouch, DG
Altenburger, DE
Townsend, DW
机构
[1] Univ Pittsburgh, Dept Radiol, PET Facil, Pittsburgh, PA 15213 USA
[2] Ecole Polytech Fed Lausanne, Lausanne, Switzerland
[3] No Digital Inc, Waterloo, ON N2L 3V2, Canada
[4] CTI PET Syst Inc, Knoxville, TN 37297 USA
关键词
D O I
10.1109/23.819283
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Head motion during PET scanning is widely regarded as a source of image degradation and resolution loss. Recent improvements in the spatial resolution of state-of-the-art tomographs may be compromised by patient motion during scanning, as these high resolution data will be increasingly susceptible to smaller movements of the head. We have developed an opto-electronic motion tracking system based on commercially-available technology that is capable of very accurate real-time measurements of the position and orientation of the patient's head. These positions are transformed to the reference frame of the PET scanner, and could potentially be used to provide motion correction of list-mode emission data on an event-by-event basis.
引用
收藏
页码:2059 / 2067
页数:9
相关论文
共 10 条
[1]  
Altmann S.A., 1986, Rotations, Quaternions and Double Groups
[2]  
Friston K., 1995, HUM BRAIN MAP, V2, P165, DOI DOI 10.1002/HBM.460030303
[3]   A head motion measurement system suitable for emission computed tomography [J].
Goldstein, SR ;
DaubeWitherspoon, ME ;
Green, MV ;
Eidsath, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (01) :17-27
[4]  
GREEN MV, 1994, J NUCL MED, V35, P1538
[5]   CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING UNIT QUATERNIONS [J].
HORN, BKP .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (04) :629-642
[6]   Compensation methods for head motion detected during PET imaging [J].
Menke, M ;
Atkins, MS ;
Buckley, KR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) :310-317
[7]   DIGITIZED VIDEO SUBJECT POSITIONING AND SURVEILLANCE SYSTEM FOR PET [J].
PICARD, Y ;
THOMPSON, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1024-1029
[8]   Motion correction of PET images using multiple acquisition frames [J].
Picard, Y ;
Thompson, CJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :137-144
[9]  
RUTTIMAN UE, 1995, PSYCHIAT RES NEUROIM, V65, P43
[10]   RAPID AUTOMATED ALGORITHM FOR ALIGNING AND RESLICING PET IMAGES [J].
WOODS, RP ;
CHERRY, SR ;
MAZZIOTTA, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (04) :620-633