Separation and characterization of rabbit liver apothioneins by capillary electrophoresis coupled to electrospray ionization time-of-flight mass spectrometry

被引:20
作者
Andon, Balbina [1 ]
Barbosa, Jose [1 ]
Sanz-Nebot, Victoria [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, Fac Quim, E-08028 Barcelona, Spain
关键词
capillary electrophoresis; CE-ESI-TOF-MS; mass spectrometry; metallothioneins;
D O I
10.1002/elps.200500168
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present study establishes a method for the separation and characterization of rabbit liver metallothionein (MT) subisoforms by capillary electrophoresis coupled to electrospray ionization time-of-flight mass spectrometry (CE-ESI-TOF-MS) via a sheath-flow interface. Directly coupled-CE-MS enables the extraction of specific molecular weight information and thereby facilitates the identification of peaks when no reference materials are available, as in the case of MT subisoforms. The analysis described here revealed the presence of the apothioneins MT-1a, MT-2d, and MT-2e, belonging to MT-I sample, and MT-2a, MT-2b, and MT-2c, belonging to MT-II. Several non-N-acetylated forms were also detected as traces appearing with their respective acetylated forms in both samples. Similar results were found when MALDI-TOF experiments were performed, identifying all the sequenced rabbit liver MTs as apo-MT-forms, as in the CE-ESI-MS coupling.
引用
收藏
页码:3661 / 3670
页数:10
相关论文
共 46 条
[1]   Detection of fast capillary electrophoresis peptide and protein separations using electrospray ionization with a time-of-flight mass spectrometer [J].
Banks, JF ;
Dresch, T .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1480-1485
[2]   Strategies for the qualitative and quantitative analysis of metallothionein isoforms by capillary electrophoresis [J].
Beattie, JH .
TALANTA, 1998, 46 (02) :255-270
[3]  
Beattie JH, 1999, ELECTROPHORESIS, V20, P1613, DOI 10.1002/(SICI)1522-2683(19990601)20:7<1613::AID-ELPS1613>3.3.CO
[4]  
2-K
[5]  
BORDIN G, 1998, INT WORKSH MET 1996, P46
[6]   Analysis of non-covalent protein complexes by capillary electrophoresis-time-of-flight mass spectrometry [J].
Brenner-Weiss, G ;
Kirschöfer, F ;
Kühl, B ;
Nusser, M ;
Obst, U .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :147-153
[7]   Polymorphism and identification of metallothionein isoforms by reversed-phase HPLC with on-line ion spray mass spectrometric detection [J].
Chassaigne, H ;
Lobinski, R .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2536-2543
[8]   Influence of matrix solution conditions on the MALDI-MS analysis of peptides and proteins [J].
Cohen, SL ;
Chait, BT .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :31-37
[9]  
Cosson RP, 2000, USE OF BIOMARKERS FOR ENVIRONMENTAL QUALITY ASSESSMENT, P79
[10]   Recent developments in quantification methods for metallothionein [J].
Dabrio, M ;
Rodríguez, AR ;
Bordin, G ;
Bebianno, MJ ;
De Ley, M ;
Sestaková, I ;
Vasák, M ;
Nordberg, M .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2002, 88 (02) :123-134