Effects of the ultrasound contrast-enhancing agent Levovist® on the detection of intracranial arteries and stenoses in Chinese by transcranial Doppler ultrasound

被引:10
作者
Hansberg, T
Wong, KSL
Droste, DW
Ringelstein, EB
Kay, R
机构
[1] Univ Munster, Dept Neurol, D-48129 Munster, Germany
[2] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Med & Therapeut, Neurol Sect, Hong Kong, Hong Kong, Peoples R China
关键词
ultrasonography; echocontrast; intracranial stenosis;
D O I
10.1159/000064742
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Proper assessment of intracranial arteries by transcranial Doppler sonography (TCD) in patients with intracranial stenoses is occasionally made difficult by an insufficient temporal bone window, an unfavourable insonation angle, or low flow velocity or volume. This condition is frequently found in Chinese. In these cases, echocontrast could be helpful. We investigated 48 temporal windows of 24 acute Chinese stroke patients with insufficient native transtemporal insonation conditions before and after the application of the echo enhancer Levovist (galactose/palmitic acid) by an injection pump. We classified the signal quality from four segments of the main intracranial arteries: anterior cerebral artery (A1), main stem of the middle cerebral artery (MCA, M1), intracranial segment of the carotid artery (C1), and posterior cerebral artery (P1). The signal quality was classified as follows: 0 = no signal, 1 = poor, envelope curve does not follow spectrum, 2 = adequate, envelope curve follows spectrum. As compared to the pre-contrast scans, echocontrast allowed for more segments to be evaluated by pulsed Doppler sonography. Before Levovist, only 12% of the segments could be detected, after Levovist 63%. For all arteries, signal quality was better after Levovist, p between 0.0180 and 0.0003. In 3 patients, MCA stenoses with peak systolic Doppler flow velocities above 160 cm/s were found only after Levovist. In patients with poor pre-contrast detection, echocontrast-enhanced TCD allows for more arterial segments to be insonated and for the detection of stenoses unnoted during the non-enhanced investigation. Copyright (C) 2002 S. Karger AG, Basel.
引用
收藏
页码:105 / 108
页数:4
相关论文
共 19 条
[1]
Burns PN, 1997, J NEUROIMAGING, V7, pS2
[2]
DEBRAY JM, 1988, J ULTRAS MED, V7, P611
[3]
Echocontrast enhanced transcranial colour-coded duplex offers improved visualization of the vertebrobasilar system [J].
Droste, DW ;
Nabavi, DG ;
Kemeny, V ;
Schulte-Altedorneburg, G ;
Ritter, MA ;
Weber, S ;
Ringelstein, EB .
ACTA NEUROLOGICA SCANDINAVICA, 1998, 98 (03) :193-199
[4]
CHINESE-WHITE DIFFERENCES IN THE DISTRIBUTION OF OCCLUSIVE CEREBROVASCULAR-DISEASE [J].
FELDMANN, E ;
DANEAULT, N ;
KWAN, E ;
HO, KJ ;
PESSIN, MS ;
LANGENBERG, P ;
CAPLAN, LR .
NEUROLOGY, 1990, 40 (10) :1541-1545
[5]
Contrast-enhanced transcranial color-coded duplex sonography - Efficiency and validity [J].
Gerriets, T ;
Seidel, G ;
Fiss, I ;
Modrau, B ;
Kaps, M .
NEUROLOGY, 1999, 52 (06) :1133-1137
[6]
Diagnostic impact and prognostic relevance of early contrast-enhanced transcranial color-coded duplex sonography in acute stroke [J].
Goertler, M ;
Kross, R ;
Baeumer, M ;
Jost, S ;
Grote, R ;
Weber, S ;
Wallesch, CW .
STROKE, 1998, 29 (05) :955-962
[7]
Vascular lesions in Chinese patients with transient ischemic attacks [J].
Huang, YN ;
Gao, S ;
Li, SW ;
Huang, Y ;
Li, JF ;
Wong, KS ;
Kay, R .
NEUROLOGY, 1997, 48 (02) :524-525
[8]
PATTERN OF CEREBRAL ATHEROSCLEROSIS IN HONG-KONG CHINESE - SEVERITY IN INTRACRANIAL AND EXTRACRANIAL VESSELS [J].
LEUNG, SY ;
NG, THK ;
YUEN, ST ;
LAUDER, IJ ;
HO, FCS .
STROKE, 1993, 24 (06) :779-786
[9]
NONINVASIVE DETECTION OF OCCLUSIVE DISEASE OF THE CAROTID SIPHON AND MIDDLE CEREBRAL-ARTERY [J].
LEYPOZO, J ;
RINGELSTEIN, EB .
ANNALS OF NEUROLOGY, 1990, 28 (05) :640-647
[10]
LINDEGAARDKF, 1992, TRANSCRANIAL DOPPLER, P161