Perturbation method for magnetic field calculations of nonconductive objects

被引:50
作者
Jenkinson, M [1 ]
Wilson, JL [1 ]
Jezzard, P [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, Oxford Ctr FMRIB, Dept Clin Neurol, Oxford OX3 9DU, England
关键词
susceptibility; distortion; simulation; field calculation;
D O I
10.1002/mrm.20194
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Inhomogeneous magnetic fields produce artifacts in MR images including signal dropout and spatial distortion. A novel perturbative method for calculating the magnetic field to first order (error is second order) within and around nonconducting objects is presented. The perturbation parameter is the susceptibility difference between the object and its surroundings (for example, similar to10 ppm in the case of brain tissue and air). This method is advantageous as it is sufficiently accurate for most purposes, can be implemented as a simple convolution with a voxel-based object model, and is linear. Furthermore, the method is simple to use and can quickly calculate the field for any orientation of an object using a set of precalculated basis images. (C) 2004 WileyLiss, Inc.
引用
收藏
页码:471 / 477
页数:7
相关论文
共 15 条
[1]   Magnetic susceptibility artifacts in Magnetic Resonance Imaging: Calculation of the magnetic field disturbances [J].
Balac, S ;
Caloz, G .
IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (03) :1645-1648
[2]   A MATHEMATICAL-MODEL OF DIAMAGNETIC LINE BROADENING IN LUNG-TISSUE AND SIMILAR HETEROGENEOUS SYSTEMS - CALCULATIONS AND MEASUREMENTS [J].
CASE, TA ;
DURNEY, CH ;
AILION, DC ;
CUTILLO, AG ;
MORRIS, AH .
JOURNAL OF MAGNETIC RESONANCE, 1987, 73 (02) :304-314
[3]   Comparison of calculated and experimental NMR spectral broadening for lung tissue [J].
Christman, RA ;
Ailion, DC ;
Case, TA ;
Durney, CH ;
Cutillo, AG ;
Shioya, S ;
Goodrich, KC ;
Morris, AH .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :6-13
[4]   Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head [J].
Collins, CM ;
Yang, B ;
Yang, QX ;
Smith, MB .
MAGNETIC RESONANCE IMAGING, 2002, 20 (05) :413-424
[5]  
FOLEY JD, 2003, COMPUTER GRAPHICS PR
[6]  
Haacke EM, 1999, MAGNETIC RESONANCE I
[7]   THE CALCULATION OF THE SUSCEPTIBILITY-INDUCED MAGNETIC-FIELD FROM 3D NMR IMAGES WITH APPLICATIONS TO TRABECULAR BONE [J].
HWANG, SN ;
WEHRLI, FW .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 109 (02) :126-145
[8]  
JENKINSON M, 2002, P 10 ANN M ISMRM HON, P2325
[9]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[10]   Three-dimensional mapping of the static magnetic field inside the human head [J].
Li, SZ ;
Dardzinski, BJ ;
Collins, CM ;
Yang, QX ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :705-714