Rapid fabrication of embossing tools for the production of polymeric microfluidic devices for bioanalytical applications

被引:9
作者
Ford, SM [1 ]
McCandless, A [1 ]
Liu, XZ [1 ]
Soper, SA [1 ]
机构
[1] Mezzo Syst Inc, Baton Rouge, LA 70803 USA
来源
MICROFLUIDICS AND BIOMEMS | 2001年 / 4560卷
关键词
SU-8; embossing; PMMA; microfluidics; LIGA; micromolding;
D O I
10.1117/12.443060
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this work we present embossing tools that were fabricated using both UV and X-ray lithography. The embossing tools created were used to emboss microfluidic channels for bioanalytical applications. Specifically, two tools were fabricated. One, using X-ray lithography, was fabricated for electrophoretic separations of DNA restriction fragment analysis. A second tool, fabricated using SU8, was designed for micro PCR applications. Depths of both tools were approximately 100 mum. Both tools were made by directly electroforming nickel on a stainless steel base. Fabrication time for the tool fabricated using X-ray lithography was less than 1 week, and largely depended on the availability of the X-ray source. The SU8 embossing tool was fabricated in less than 24 hours. The resulting nickel electroforms from both processes were extremely robust and did not fail under embossing conditions required for PMMA and/or polycarbonate. Some problems removing SU8 after electroforming were seen for smaller size gaps between nickel structures.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 27 条
[1]   Fabrication of topologically complex three-dimensional microfluidic systems in PDMS by rapid prototyping [J].
Anderson, JR ;
Chiu, DT ;
Jackman, RJ ;
Cherniavskaya, O ;
McDonald, JC ;
Wu, HK ;
Whitesides, SH ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3158-3164
[2]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[3]  
2-7
[4]  
Becker H, 1999, SENSOR MATER, V11, P297
[5]   Isotachophoresis and isotachophoresis -: zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection [J].
Bodor, R ;
Madajová, V ;
Kaniansky, D ;
Masár, M ;
Jöhnck, M ;
Stanislawski, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :155-165
[6]  
Chen YH, 2000, ELECTROPHORESIS, V21, P165, DOI 10.1002/(SICI)1522-2683(20000101)21:1<165::AID-ELPS165>3.0.CO
[7]  
2-I
[8]  
Ford SM, 1998, J MICROCOLUMN SEP, V10, P413, DOI 10.1002/(SICI)1520-667X(1998)10:5<413::AID-MCS4>3.0.CO
[9]  
2-J
[10]   A new PMMA-microchip device for isotachophoresis with integrated conductivity detector [J].
Grass, B ;
Neyer, A ;
Jöhnck, M ;
Siepe, D ;
Eisenbeiss, F ;
Weber, G ;
Hergenröder, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) :249-258