Metabolomic database annotations via query of elemental compositions:: Mass accuracy is insufficient even at less than 1 ppm

被引:471
作者
Kind, Tobias [1 ]
Fiehn, Oliver [1 ]
机构
[1] Univ Calif Davis, Genome Ctr, Davis, CA 95616 USA
关键词
D O I
10.1186/1471-2105-7-234
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Metabolomic studies are targeted at identifying and quantifying all metabolites in a given biological context. Among the tools used for metabolomic research, mass spectrometry is one of the most powerful tools. However, metabolomics by mass spectrometry always reveals a high number of unknown compounds which complicate in depth mechanistic or biochemical understanding. In principle, mass spectrometry can be utilized within strategies of de novo structure elucidation of small molecules, starting with the computation of the elemental composition of an unknown metabolite using accurate masses with errors < 5 ppm (parts per million). However even with very high mass accuracy (< 1 ppm) many chemically possible formulae are obtained in higher mass regions. In automatic routines an additional orthogonal filter therefore needs to be applied in order to reduce the number of potential elemental compositions. This report demonstrates the necessity of isotope abundance information by mathematical confirmation of the concept. Results: High mass accuracy (< 1 ppm) alone is not enough to exclude enough candidates with complex elemental compositions (C, H, N, S, O, P, and potentially F, Cl, Br and Si). Use of isotopic abundance patterns as a single further constraint removes > 95% of false candidates. This orthogonal filter can condense several thousand candidates down to only a small number of molecular formulas. Example calculations for 10, 5, 3, 1 and 0.1 ppm mass accuracy are given. Corresponding software scripts can be downloaded from http:// fiehnlab. ucdavis. edu. A comparison of eight chemical databases revealed that PubChem and the Dictionary of Natural Products can be recommended for automatic queries using molecular formulae. Conclusion: More than 1.6 million molecular formulae in the range 0 - 500 Da were generated in an exhaustive manner under strict observation of mathematical and chemical rules. Assuming that ion species are fully resolved (either by chromatography or by high resolution mass spectrometry), we conclude that a mass spectrometer capable of 3 ppm mass accuracy and 2% error for isotopic abundance patterns outperforms mass spectrometers with less than 1 ppm mass accuracy or even hypothetical mass spectrometers with 0.1 ppm mass accuracy that do not include isotope information in the calculation of molecular formulae.
引用
收藏
页数:10
相关论文
共 38 条
[1]  
*ACD MS FRAGM, 2005, MASS SPECTR FRAGM AN
[2]  
Balogh MP, 2004, LC GC N AM, V22, P118
[3]   Intercomparison study on accurate mass measurement of small molecules in mass spectrometry [J].
Bristow, AWT ;
Webb, KS .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (10) :1086-1098
[4]   Atomic weights of the elements:: Review 2000 -: (IUPAC technical report) [J].
De Laeter, JR ;
Böhlke, JK ;
De Bièvre, P ;
Hidaka, H ;
Peiser, HS ;
Rosman, KJR ;
Taylor, PDP .
PURE AND APPLIED CHEMISTRY, 2003, 75 (06) :683-800
[5]   STOCHASTIC GENERATOR OF CHEMICAL-STRUCTURE .1. APPLICATION TO THE STRUCTURE ELUCIDATION OF LARGE MOLECULES [J].
FAULON, JL .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 1994, 34 (05) :1204-1218
[6]   Combining genomics, metabolome analysis, and biochemical modelling to understand metabolic networks [J].
Fiehn, O .
COMPARATIVE AND FUNCTIONAL GENOMICS, 2001, 2 (03) :155-168
[7]  
FIEHN O, 2005, EXACT MOL MASS DETER
[8]   An MS/MS library on an ion-trap instrument for efficient dereplication of natural products.: Different fragmentation patterns for [M+H]+ and [M+Na]+ ions [J].
Fredenhagen, A ;
Derrien, C ;
Gassmann, E .
JOURNAL OF NATURAL PRODUCTS, 2005, 68 (03) :385-391
[9]   Utility of three types of mass spectrometers for determining elemental compositions of ions formed from chromatographically separated compounds [J].
Grange, AH ;
Genicola, FA ;
Sovocool, GW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (24) :2356-2369
[10]   SIMPLE TOOLS FOR THE COMPUTER-AIDED INTERPRETATION OF MASS-SPECTRA [J].
HEUERDING, S ;
CLERC, JT .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1993, 20 (01) :57-69