An MS/MS library on an ion-trap instrument for efficient dereplication of natural products.: Different fragmentation patterns for [M+H]+ and [M+Na]+ ions

被引:60
作者
Fredenhagen, A [1 ]
Derrien, C [1 ]
Gassmann, E [1 ]
机构
[1] Syngenta Crop Protect AG, CPR Analyt, Basel, Switzerland
来源
JOURNAL OF NATURAL PRODUCTS | 2005年 / 68卷 / 03期
关键词
D O I
10.1021/np049657e
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
The structural novelty of lead compounds is very important in the agrochemical and pharmaceutical industries, and as such, natural products can be an important source. Taking into account that the isolation of lead compounds is very time-consuming, the efficient and safe identification of compounds in microorganism and plant extracts isolated previously is essential. A suitable procedure for this task based on an HPLC system interfaced with an electrospray (ESI) source and a Thermo Finnigan LCQ deca XP plus ion-trap mass spectrometer was developed, and an extensive MS/MS spectral library of characterized natural products was built up. This report summarizes the parameters used for acquiring the library spectra and discusses current limitations of the NIST library and search algorithm. The advantages of the newly introduced Mass Frontier 4.0 for the search of MS/MS product-ion spectra are discussed. Different mechanisms for fragmentation of some [M + H](+) and [M + Na](+) ions that were found are proposed. Oligomycin A, a macrolide antibiotic, exhibits different fragmentation mechanisms in positive and negative ion modes. The cleavage of the ester bond is the preferred mechanism in the positive ion mode, whereas two different pathways-one showing a rare retro-Michael-addition-are observed in the negative ion mode.
引用
收藏
页码:385 / 391
页数:7
相关论文
共 29 条
[1]   Structural analysis of phosphatidylcholines by post-source decay matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Al-Saad, KA ;
Siems, WF ;
Hill, HH ;
Zabrouskov, V ;
Knowles, NR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (04) :373-382
[2]  
Baumann C, 2000, RAPID COMMUN MASS SP, V14, P349, DOI 10.1002/(SICI)1097-0231(20000315)14:5<349::AID-RCM873>3.3.CO
[3]  
2-G
[4]   STRUCTURE DETERMINATION OF OLIGOMYCIN-A AND OLIGOMYCIN-C1A [J].
CARTER, GT .
JOURNAL OF ORGANIC CHEMISTRY, 1986, 51 (22) :4264-4271
[5]   FAST-ATOM-BOMBARDMENT AND TANDEM MASS-SPECTROMETRY OF MACROLIDE ANTIBIOTICS [J].
CERNY, RL ;
MACMILLAN, DK ;
GROSS, ML ;
MALLAMS, AK ;
PRAMANIK, BN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (03) :151-158
[6]   A METHOD FOR THE DEREPLICATION OF NATURAL PRODUCT EXTRACTS USING ELECTROSPRAY HPLC/MS [J].
CONSTANT, HL ;
BEECHER, CWW .
NATURAL PRODUCT LETTERS, 1995, 6 (03) :193-196
[7]   Finding the needle in the haystack. The dereplication of natural product extracts [J].
Cordell, GA ;
Shin, YG .
PURE AND APPLIED CHEMISTRY, 1999, 71 (06) :1089-1094
[8]   STRATEGIES FOR DATABASE DEREPLICATION OF NATURAL-PRODUCTS [J].
CORLEY, DG ;
DURLEY, RC .
JOURNAL OF NATURAL PRODUCTS-LLOYDIA, 1994, 57 (11) :1484-1490
[9]   High-throughput analysis of natural product compound libraries by parallel LC-MS evaporative light scattering detection [J].
Cremin, PA ;
Zeng, L .
ANALYTICAL CHEMISTRY, 2002, 74 (21) :5492-5500
[10]   MASS-SPECTROMETRIC TECHNIQUES FOR STRUCTURE AND NOVELTY DETERMINATION OF KIRROMYCIN-LIKE ANTIBIOTICS [J].
EDWARDS, DMF ;
SELVA, E ;
STELLA, S ;
ZERILLI, LF ;
GALLO, GG .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (01) :51-59