Quantification of malachite green in fish feed utilising liquid chromatography-tandem mass spectrometry with a monolithic column

被引:18
作者
Abro, Kamran [1 ]
Mahesar, Sarfaraz Ahmed [2 ]
Iqbal, Seema [1 ]
Perveen, Shahnaz [1 ]
机构
[1] Pakistan Council Sci & Ind Res Labs Complex, Pharmaceut Res Ctr, Karachi, Pakistan
[2] Univ Sindh Jamshoro, Natl Ctr Excellence Analyt Chem, Jamshoro, Pakistan
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2014年 / 31卷 / 05期
关键词
malachite green; SRM; LC-ESI-MS/MS; fish feeds; monolithic column; PRESSURE CHEMICAL-IONIZATION; CRYSTAL VIOLET; LEUCOMALACHITE GREEN; RAMAN-SPECTROSCOPY; RAINBOW-TROUT; SEPARATION; PRODUCTS; RESIDUES; WATER; ELECTROSPRAY;
D O I
10.1080/19440049.2014.893398
中图分类号
O69 [应用化学];
学科分类号
070301 [无机化学];
摘要
The purpose of this study was to develop a rapid and sensitive method for the quantification of malachite green (MG) in fish feed using LC-ESI-MS/MS with a monolithic column as stationary phase. Fish feed was cleaned using ultrasonic assisted liquid-liquid extraction. The separation was achieved on a Chromolith((R)) Performance RP-18e column (100x4.6mm) using gradient mobile phase composition of methanol and 0.1% formic acid at the flow rate of 1.0mlmin(-1). The analyte was ionised using electrospray ionisation in positive mode. Mass spectral transitions were recorded in selected reaction monitoring (SRM) mode at m/z 329.78 -> m/z 314.75 with a collision energy (CE) of 52% for MG. The system suitability responses were calculated for reproducibility tests of the retention time, number of theoretical plates and capacity factor. System validation was evaluated for precision, specificity and linearity of MG. The linearity and calibration graph was plotted in the range of 15.0-250ngml(-1) with the regression coefficient of >0.997. The lower limits of detection and quantification for MG were 0.55 and 1.44ngml(-1), respectively, allowing easy determination in fish feed with accuracy evaluated as a percentage recovery of 92.1% and precision determined as % CV of <5. The method was also extended to the determination of MG in an actual fish feed. The sensitivity and selectivity of LC-ESI-MS/MS using monolithic column offers a valuable alternative to the methodologies currently employed for the quantification of MG in fish feeds.
引用
收藏
页码:827 / 832
页数:6
相关论文
共 30 条
[1]
Abro K, 2011, PAK J ANAL ENV CHEM, V12, P49
[2]
DETERMINATION OF VITAMINS E, D3, AND K1 IN PLASMA BY LIQUID CHROMATOGRAPHY-ATMOSPHERIC PRESSURE CHEMICAL IONIZATION-MASS SPECTROMETRY UTILIZING A MONOLITHIC COLUMN [J].
Abro, Kamran ;
Memon, Najma ;
Bhanger, M. I. ;
Abro, Suhail ;
Perveen, Shahnaz ;
Laghari, A. H. .
ANALYTICAL LETTERS, 2014, 47 (01) :14-24
[3]
MULTI-COMPONENT QUANTITATION OF LORATADINE, PSEUDOEPHEDRINE AND PARACETAMOL IN PLASMA AND PHARMACEUTICAL FORMULATIONS WITH LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY UTILIZING A MONOLITHIC COLUMN [J].
Abro, Kamran ;
Memon, Najma ;
Bhanger, M. I. ;
Perveen, Shahnaz ;
Kandhro, Aftab .
QUIMICA NOVA, 2012, 35 (10) :1950-1954
[4]
COMPARATIVE STUDY OF ELECTROSPRAY AND ATMOSPHERIC PRESSURE CHEMICAL IONIZATION WITH LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY FOR QUANTIFICATION OF FIVE ANTIHYPERGLYCEMIC AGENTS UTILIZING MONOLITHIC COLUMN [J].
Abro, Kamran ;
Memon, Najma ;
Bhanger, M. I. ;
Perveen, Shahnaz ;
Panhwar, Aijaz .
ANALYTICAL LETTERS, 2012, 45 (14) :1947-1959
[5]
Abro Kamran, 2011, Pakistan Journal of Scientific and Industrial Research Series A-Physical Sciences, V54, P103
[6]
MALACHITE GREEN - A PHARMACOKINETIC STUDY IN RAINBOW-TROUT, ONCORHYNCHUS-MYKISS (WALBAUM) [J].
ALDERMAN, DJ ;
CLIFTONHADLEY, RS .
JOURNAL OF FISH DISEASES, 1993, 16 (04) :297-311
[7]
Validation of an LC-MS/MS method for malachite green (MG), leucomalachite green (LMG), crystal violet (CV) and leucocrystal violet (LCV) residues in fish and shrimp [J].
Ascari, Jociani ;
Dracz, Sergio ;
Santos, Flavio A. ;
Lima, J. A. ;
Diniz, Maria Helena G. ;
Vargas, Eugenia A. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (04) :602-608
[8]
Development of cloud point extraction using pH-sensitive hydrogel for preconcentration and determination of malachite green [J].
Bahram, Morteza ;
Keshvari, Foroogh ;
Najafi-Moghaddam, Peyman .
TALANTA, 2011, 85 (02) :891-896
[9]
Commission Decision, 2004, OFFICIAL J EUROPEAN, VL6, P38
[10]
Culp S. J., 1996, INT J TOXICOL, V15, P219