Experimental comparison of monofile light and heavy polypropylene meshes:: Less weight does not mean less biological response

被引:76
作者
Weyhe, Dirk
Schmitz, Inge
Belyaev, Orlin
Grabs, Robert
Mueller, Klaus-Michael
Uhl, Waldemar
Zumtobel, Volker
机构
[1] Ruhr Univ Bochum, St Josef Hosp, Univ Med Ctr, Dept Surg, D-44791 Bochum, Germany
[2] Ruhr Univ Bochum, Bergmannsheil Hosp, Inst Pathol, D-4630 Bochum, Germany
关键词
D O I
10.1007/s00268-005-0601-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Mesh implantation is a standard procedure in hernia repair. It provides low recurrence rate but increases complication rate due to foreign-body reaction induced by alloplastic materials in surrounding tissues. It is believed that biocompatibility of meshes may be improved by reducing their weight per meter squared (m(2)) and altering the implant structure. Aim: The aim of this study was to evaluate the effect of weight and structure as determinants of mesh biocompatibility. Method. Thirty-six Wistar rats were studied. In 12 animals, conventional polypropylene (heavy) meshes (HM) were implanted; in other 12, material-reduced (light) microporous polypropylene meshes (LM); and the remaining 12 served as a sham-operated control group. Meshes were explanted after 21 and 90 days (6 animals per group). All samples were examined by light and electron microscopies. Integration of meshes in surrounding tissue, inflammatory response, fibrotic reactions, and structural changes were recorded. Quantification of the inflammatory response was achieved by CD-68 marking of macrophages and counting their number per surface unit. Results: After 21 days, there was no significant difference in thickness of surrounding connective tissue between meshes in all groups studied. After 90 days, thickness of connective tissue decreased in both groups, and fibrotic reaction in the mesh bed was significantly less in the HIM group. Total amount of macrophages per millimeter squared (mm(2)) decreased with time in HM and LM samples but was significantly lower in the HIM group on day 21 (43.5%) and day 90 (46.7%). Conclusion: This study found worse biocompatibility of LM compared with HM. Thus, the amount of implanted mesh was not the main determinant of biocompatibility (expressed as successful incorporation and diminished foreign-body reaction) but the size of the pores.
引用
收藏
页码:1586 / 1591
页数:6
相关论文
共 19 条
[1]   INTEGRATION OF BIOMATERIALS IMPLANTED INTO ABDOMINAL-WALL - PROCESS OF SCAR FORMATION AND MACROPHAGE RESPONSE [J].
BELLON, JM ;
BUJAN, J ;
CONTRERAS, L ;
HERNANDO, A .
BIOMATERIALS, 1995, 16 (05) :381-387
[2]  
Bittner R, 1996, ZBL CHIR, V121, P313
[3]  
Coda A, 2000, HERNIA, V4, P206
[4]  
FOLSCHER DJ, 2000, HERNIA, V4, P228
[5]  
Greca F H, 2001, Hernia, V5, P59
[6]   Late mesh rejection as a complication to transabdominal preperitoneal laparoscopic hernia repair [J].
Hofbauer, C ;
Andersen, PV ;
Juul, P ;
Qvist, N .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1998, 12 (09) :1164-1165
[7]  
Junge K, 2001, Hernia, V5, P113
[8]  
Klinge U, 1999, EUR J SURG, V165, P665
[9]  
Klinge U, 1998, EUR J SURG, V164, P965
[10]   Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair [J].
Klinge, U ;
Junge, K ;
Stumpf, M ;
Öttinger, AP ;
Klosterhalfen, B .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (02) :129-136