We apply electrical impedance tomography to detect and localize brain impedance changes associated with stroke. Forward solutions are computed using the finite-element method in two dimensions. We assume that baseline conductivity values are known for the major head tissues, and focus on changes in the brain compartment only. We use singular-value decomposition (SVD) to show that different impedance measurement patterns, which are theoretically equivalent by the reciprocity theorem, have different sensitivities to the brain compartment in the presence of measurement noise. The inverse problem is solved in part by standard means, using iterated SVD, and regularizing by truncation. To improve regularization we introduce a weighting scheme which normalizes the sensitivity matrix for voxels at different depths. This increases the number of linearly independent components which contribute to the solution, and forces the different measurement patterns to have similar sensitivity. When applied to stroke, this weighted regularization improves image quality overall.
引用
收藏
页码:629 / 637
页数:9
相关论文
共 45 条
[1]   Antithrombotic and thrombolytic therapy for ischemic stroke [J].
Albers, GW ;
Easton, JD ;
Sacco, RL ;
Teal, P .
CHEST, 1998, 114 (05) :683S-698S
[2]  
[Anonymous], FINITE ELEMENT METHO
[3]  
[Anonymous], 1969, BIOMAGNETIC PHENOMEN
[4]   Effect of conductivity uncertainties and modeling errors on EEG source localization using a 2-D model [J].
Awada, KA ;
Jackson, DR ;
Baumann, SB ;
Williams, JT ;
Wilton, DR ;
Fink, PW ;
Prasky, BR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (09) :1135-1145
[5]   Prediction of stroke outcome with echoplanar perfusion- and diffusion-weighted MRI [J].
Barber, PA ;
Darby, DG ;
Desmond, PM ;
Yang, Q ;
Gerraty, RP ;
Jolley, D ;
Donnan, GA ;
Tress, BM ;
Davis, SM .
NEUROLOGY, 1998, 51 (02) :418-426
[6]   The electrical conductivity of human cerebrospinal fluid at body temperature [J].
Baumann, SB ;
Wozny, DR ;
Kelly, SK ;
Meno, FM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) :220-223
[7]   Improvement of the positional accuracy of EIT images of the head using a Lagrange multiplier reconstruction algorithm with diametric excitation [J].
Bayford, RH ;
Boone, KG ;
Hanquan, Y ;
Holder, DS .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A49-A57
[8]  
BOONE KG, 1995, THESIS U LONDON
[9]  
Chen TT, 1999, MAR BIOTECHNOL, V1, P1
[10]   ESTIMATION OF TISSUE RESISTIVITIES FROM MULTIPLE-ELECTRODE IMPEDANCE MEASUREMENTS [J].
EYUBOGLU, BM ;
PILKINGTON, TC ;
WOLF, PD .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (01) :1-17