Usefulness of rotational spin for coronary angiography in patients with advanced renal insufficiency

被引:28
作者
Kuon, E
Niederst, PN
Dahm, JB
机构
[1] Klin Fraenk Schweiz, Dept Cardiol, D-91320 Ebermannstadt, Germany
[2] Univ Greifswald, Dept Cardiol, Greifswald, Germany
关键词
D O I
10.1016/S0002-9149(02)02491-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary angiography in patients with advanced renal insufficiency is typically restricted to cases of life-threatening circumstances such as acute myocardial infarction and unstable angina. To gather a large amount of visual information with a minimum number of cine runs, and consequently, with a minimum volume of contrast medium, we rotated the gantry at 40degrees/s throughout an angle of 120degrees, from the right toward the left anterior oblique positions. This technique of rotational spin during cinegraphic runs has not yet become established in invasive cardiology. Three experienced cardiologists independently evaluated all coronary segments in rotational versus standard coronary angiography modes for 15 patients, on the basis of an I I-point scale (0 = cardiac spin for better to 10 = standard mode far better). A score of 5 signified that there was no difference in quality between the 2 modes. The arithmetic mean of the assessment values was 4.9 +/- 0.3 for coronary segments, 5.4 +/- 1.3 for coronary lesions, 5.1 +/- 1.4 for bifurcations, and 5.0 +/- 0.1 for coronary flow. The arithmetic means for the volume of contrast medium (25 +/- 4 ml), for the overall dose area product (8.6 +/- 4.5 Gy x cm(2)), and for the number of cine graphic frames (203 +/- 65) for a diagnostic cardiac spin were significantly below published typical values in standard mode. Cardiac spin enables 3-dimensional coronary impression under conditions of adequate image quality and represents a new, useful, and beneficial method in invasive cardiology for applications involving the special indication of advanced renal insufficiency. (C) 2002 by Excerpta Medica, Inc.
引用
收藏
页码:369 / 373
页数:5
相关论文
共 27 条
[1]  
Aldridge HE, 1997, CAN J CARDIOL, V13, P459
[2]  
Bakalyar DM, 1997, CATHETER CARDIO DIAG, V42, P121, DOI 10.1002/(SICI)1097-0304(199710)42:2<121::AID-CCD4>3.3.CO
[3]  
2-Y
[4]  
Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
[5]   Patient radiation doses during cardiac catheterization procedures [J].
Betsou, S ;
Efstathopoulos, EP ;
Katritsis, D ;
Faulkner, K ;
Panayiotakis, G .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846) :634-639
[6]   The impact of cardiology on the collective effective dose in the North of England [J].
Broadhead, DA ;
Chapple, CL ;
Faulkner, K ;
Davies, ML ;
McCallum, H .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (833) :492-497
[7]   Factors affecting patient radiation exposure during routine coronary angiography in a tertiary referral centre [J].
Clark, AL ;
Brennan, AG ;
Robertson, LJ ;
McArthur, JD .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (866) :184-189
[8]   Radiation exposure in multi-slice CT of the heart [J].
Cohnen, M ;
Poll, L ;
Püttmann, C ;
Ewen, K ;
Mödder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04) :295-299
[9]   Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures [J].
Cusma, JT ;
Bell, MR ;
Wondrow, MA ;
Taubel, JP ;
Holmes, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) :427-435
[10]   Chronic radiodermatitis following cardiac catheterisation:: a report of two cases and a brief review of the literature [J].
Dehen, L ;
Vilmer, C ;
Humilière, C ;
Corcos, T ;
Pentousis, D ;
Ollivaud, L ;
Chatelain, D ;
Dubertret, L .
HEART, 1999, 81 (03) :308-312