Finapres arterial pulse wave analysis with Modeflow® is not a reliable non-invasive method for assessment of cardiac output

被引:63
作者
Remmen, JJ [1 ]
Aengevaeren, WRM [1 ]
Verheugt, FWA [1 ]
van der Werf, T [1 ]
Luijten, HE [1 ]
Bos, A [1 ]
Jansen, RWMM [1 ]
机构
[1] Univ Med Ctr Nijmegen, Dept Cariol, Heartctr, Dept Geriatr Med, NL-6500 HB Nijmegen, Netherlands
关键词
aged; blood pressure; cardiac output; cardiovascular diagnostic techniques; cardiovascular model; pulse;
D O I
10.1042/CS20010357
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Non-invasive continuous monitoring of cardiac output could be very useful in clinical care and in research settings, particularly in elderly subjects. We studied whether Finapres arterial pulse wave analysis with Modelflow(R) is a reliable non-invasive method for the assessment of cardiac output in healthy elderly subjects. We compared Modelflow(R) cardiac output (MFCO) with thermodilution cardiac output (TDCO) in 28 healthy subjects, aged 70 +/- 4 years (mean +/- S.D.). TDCO was measured during right-sided heart catheterization, while MFCO was calculated with Modelflow(R) software from non-invasive arterial Finapres blood pressure, which was measured simultaneously. The two methods were compared using a paired t-test, by Pearson correlation, and by Bland-Altman analysis. TDCO was 6.4 +/- 1.1 litres/min (mean +/- S.D.) and MFCO was 4.7 +/- 1.3 litres/min (P < 0.00 1). There was no significant correlation between MFCO and TDCO (r = 0.28, P = 0. 13). Mean difference (bias) was - 1.7 litres/min (S.E.M. 0.27 litres/min), with an S.D. (precision) of 1.5 litres/min. The 95% limits of agreement were -4.6 to + 1. 1 litres/min. In conclusion, non-invasive MFCO values differed significantly from and showed no significant correlation with invasively determined TDCO values in the normal range. Although simple, non-invasive and patient-friendly, the Modelflow(R) method is inaccurate for assessment of cardiac output without invasive calibration.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 29 条
[1]  
[Anonymous], 1997, Cardiovasc Res, V35, P2
[2]  
[Anonymous], 1997, ARCH INTERN MED, V157, P2413, DOI [10.1001/archinte.1997.00440420033005, DOI 10.1001/ARCHINTE.1997.00440420033005]
[3]  
Bland JM, 1996, BRIT MED J, V313, P744
[4]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[5]  
Boon D, 2001, PERITON DIALYSIS INT, V21, P166
[6]   THE RELIABILITY OF NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT IN PATIENTS WITH BOTH HYPERTENSION AND VASCULAR-DISEASE [J].
BOS, WJW ;
IMHOLZ, BPM ;
VANGOUDOEVER, J ;
WESSELING, KH ;
VANMONTFRANS, GA .
AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (08) :529-535
[7]   Reconstruction of brachial artery pressure from noninvasive finger pressure measurements [J].
Bos, WJW ;
vanGoudoever, J ;
vanMontfrans, GA ;
vandenMeiracker, AH ;
Wesseling, KH .
CIRCULATION, 1996, 94 (08) :1870-1875
[8]   Cardiac and hemodynamic effects of hemodialysis and ultrafiltration [J].
Bos, WJW ;
Bruin, S ;
van Olden, RW ;
Keur, I ;
Wesseling, KH ;
Westerhof, N ;
Krediet, RT ;
Arisz, LA .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 35 (05) :819-826
[9]   THERMODILUTION METHOD FOR MEASURING CARDIAC-OUTPUT [J].
CONWAY, J ;
LUNDJOHANSEN, P .
EUROPEAN HEART JOURNAL, 1990, 11 :17-20
[10]   Left ventricular diastolic filling in the elderly: The Cardiovascular Health Study [J].
Gardin, JM ;
Arnold, AM ;
Bild, DE ;
Smith, VE ;
Lima, JAC ;
Klopfenstein, HS ;
Kitzman, DW .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (03) :345-351