Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography

被引:123
作者
Rofsky, NM [1 ]
Johnson, G [1 ]
Adelman, MA [1 ]
Rosen, RJ [1 ]
Krinsky, GA [1 ]
Weinreb, JC [1 ]
机构
[1] NYU,MED CTR,DEPT SURG,DIV VASC SURG,NEW YORK,NY 10016
关键词
angiography; comparative studies; arteries; extremities; stenosis or obstruction; gadolinium; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.205.1.9314979
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To demonstrate the utility of low-dose gadolinium-enhanced magnetic resonance (MR) angiography of two consecutive anatomic areas for assessment of peripheral vascular disease. MATERIALS AND METHODS: Fifteen patients underwent gadolinium-enhanced MR angiography for evaluation of lower extremity peripheral vascular disease after conventional digital subtraction angiography (DSA). MR angiography was performed with three-dimensional coronal gradient-echo acquisitions before and during administration of gadopentetate dimeglumine. Two separate, contiguous areas were studied with separate doses of 0.075 and 0.1 mmol/kg gadopentetate dimeglumine. MR angiography findings were compared with DSA findings; DSA was the standard of reference. Treatment options were determined first with MR angiograms and then with DSA images. RESULTS: For distinguishing greater than 50% stenosis from 50% or less stenosis, gadolinium-enhanced MR angiography yielded a sensitivity of 97%, a specificity of 96%, and an accuracy of 97%. In 146 (97%) of 150 anatomic segments, there was essential or total agreement on treatments determined with MR angiography and DSA. In two cases (one case of vascular stent placement and one case of surgical anastomosis), extent of disease was overestimated with MR angiography. The MR study of one infrapopliteal area was insufficient for evaluation. CONCLUSION: Accurate gadolinium-enhanced MR angiography of multiple peripheral vascular areas of the lower extremities can be performed in most patients with less than 0.2 mmol/kg contrast material.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 31 条
[1]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[2]   MULTICENTER TRIAL TO EVALUATE VASCULAR MAGNETIC-RESONANCE ANGIOGRAPHY OF THE LOWER-EXTREMITY [J].
BAUM, RA ;
RUTTER, CM ;
SUNSHINE, JH ;
BLEBEA, JS ;
BLEBEA, J ;
CARPENTER, JP ;
DICKEY, KW ;
QUINN, SF ;
GOMES, AS ;
GRIST, TM ;
MCNEIL, BJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (11) :875-880
[3]   MR angiography of tibial runoff vessels: Imaging with the head coil compared with conventional arteriography [J].
Cortell, ED ;
Kaufman, JA ;
Geller, SC ;
Cambria, RP ;
Rivitz, SM ;
Waltman, AC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :147-151
[4]   PRIMARY AND ADJUNCTIVE INTRAARTERIAL DIGITAL SUBTRACTION ARTERIOGRAPHY OF THE LOWER-EXTREMITIES [J].
DARDIK, H ;
MILLER, N ;
ADLER, J ;
GANTI, SR ;
MYERS, D ;
GREWELDINGER, J ;
IBRAHIM, IM ;
SUSSMAN, B ;
KAHN, M .
JOURNAL OF VASCULAR SURGERY, 1986, 3 (04) :599-604
[5]   FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE [J].
DOUEK, PC ;
REVEL, D ;
CHAZEL, S ;
FALISE, B ;
VILLARD, J ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :431-437
[6]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[7]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[8]   Cardiac-gated MR angiography of the entire lower extremity: A prospective comparison with conventional angiography [J].
Glickerman, DJ ;
Obregon, RG ;
Schmiedl, UP ;
Harrison, SD ;
Macaulay, SE ;
Simon, HE ;
Kohler, TR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :445-451
[9]   RENAL TOLERANCE OF GADOLINIUM-DTPA DIMEGLUMINE IN PATIENTS WITH CHRONIC-RENAL-FAILURE [J].
HAUSTEIN, J ;
NIENDORF, HP ;
KRESTIN, G ;
LOUTON, T ;
SCHUHMANNGIAMPIERI, G ;
CLAUSS, W ;
JUNGE, W .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :153-156
[10]   Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries [J].
Holland, GA ;
Dougherty, L ;
Carpenter, JP ;
Golden, MA ;
Gilfeather, M ;
Slossman, F ;
Schnall, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :971-981