Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography

被引:123
作者
Rofsky, NM [1 ]
Johnson, G [1 ]
Adelman, MA [1 ]
Rosen, RJ [1 ]
Krinsky, GA [1 ]
Weinreb, JC [1 ]
机构
[1] NYU,MED CTR,DEPT SURG,DIV VASC SURG,NEW YORK,NY 10016
关键词
angiography; comparative studies; arteries; extremities; stenosis or obstruction; gadolinium; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.205.1.9314979
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To demonstrate the utility of low-dose gadolinium-enhanced magnetic resonance (MR) angiography of two consecutive anatomic areas for assessment of peripheral vascular disease. MATERIALS AND METHODS: Fifteen patients underwent gadolinium-enhanced MR angiography for evaluation of lower extremity peripheral vascular disease after conventional digital subtraction angiography (DSA). MR angiography was performed with three-dimensional coronal gradient-echo acquisitions before and during administration of gadopentetate dimeglumine. Two separate, contiguous areas were studied with separate doses of 0.075 and 0.1 mmol/kg gadopentetate dimeglumine. MR angiography findings were compared with DSA findings; DSA was the standard of reference. Treatment options were determined first with MR angiograms and then with DSA images. RESULTS: For distinguishing greater than 50% stenosis from 50% or less stenosis, gadolinium-enhanced MR angiography yielded a sensitivity of 97%, a specificity of 96%, and an accuracy of 97%. In 146 (97%) of 150 anatomic segments, there was essential or total agreement on treatments determined with MR angiography and DSA. In two cases (one case of vascular stent placement and one case of surgical anastomosis), extent of disease was overestimated with MR angiography. The MR study of one infrapopliteal area was insufficient for evaluation. CONCLUSION: Accurate gadolinium-enhanced MR angiography of multiple peripheral vascular areas of the lower extremities can be performed in most patients with less than 0.2 mmol/kg contrast material.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 31 条
[21]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[22]   GADOLINIUM-ENHANCED MR AORTOGRAPHY [J].
PRINCE, MR .
RADIOLOGY, 1994, 191 (01) :155-164
[23]   GADOLINIUM-ENHANCED MAGNETIC-RESONANCE ANGIOGRAPHY OF ABDOMINAL AORTIC-ANEURYSMS [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
WAKEFIELD, TW ;
MESSINA, LM ;
ZELENOCK, GB ;
JACOBY, WT ;
MARX, MV ;
WILLIAMS, DM ;
CHO, KJ .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (04) :656-669
[24]   Nephrotoxicity of high-dose gadolinium compared with iodinated contrast [J].
Prince, MR ;
Arnoldus, C ;
Frisoli, JK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) :162-166
[25]   RENAL LESION CHARACTERIZATION WITH GADOLINIUM-ENHANCED MR IMAGING - EFFICACY AND SAFETY IN PATIENTS WITH RENAL-INSUFFICIENCY [J].
ROFSKY, NM ;
WEINREB, JC ;
BOSNIAK, MA ;
LIBES, RB ;
BIRNBAUM, BA .
RADIOLOGY, 1991, 180 (01) :85-89
[26]  
RUNGE VM, 1995, TOP MAGN RESON IMAG, V7, P181
[27]   ILIAC ARTERY NIR ANGIOGRAPHY - COMPARISON OF 3-DIMENSIONAL GADOLINIUM-ENHANCED AND 2-DIMENSIONAL TIME-OF-FLIGHT TECHNIQUES [J].
SNIDOW, JJ ;
AISEN, AM ;
HARRIS, VJ ;
TREROTOLA, SO ;
JOHNSON, MS ;
SAWCHUK, AP ;
DALSING, MC .
RADIOLOGY, 1995, 196 (02) :371-378
[28]  
Tartaro A, 1992, Radiol Med, V84, P536
[29]  
Tweedle MF, 1992, INVEST RADIOL, V27, P2
[30]   ATHEROSCLEROTIC OCCLUSIVE DISEASE OF THE LOWER-EXTREMITY - PROSPECTIVE EVALUATION WITH 2-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY [J].
YUCEL, EK ;
KAUFMAN, JA ;
GELLER, SC ;
WALTMAN, AC .
RADIOLOGY, 1993, 187 (03) :637-641