共 23 条
Comparative Analysis of Logistic Regression, Support Vector Machine and Artificial Neural Network for the Differential Diagnosis of Benign and Malignant Solid Breast Tumors by the Use of Three-Dimensional Power Doppler Imaging
被引:29
作者:
Chen, Shou-Tung
[2
]
Hsiao, Yi-Hsuan
[3
]
Huang, Yu-Len
[4
]
Kuo, Shou-Jen
[1
,2
]
Tseng, Hsin-Shun
[2
,3
]
Wu, Hwa-Koon
[5
]
Chen, Dar-Ren
[1
,2
,3
]
机构:
[1] Changhua Christian Hosp, Comprehens Breast Canc Ctr, Changhua 500, Taiwan
[2] Changhua Christian Hosp, Dept Surg, Changhua 500, Taiwan
[3] Changhua Christian Hosp, Dept Res, Changhua 500, Taiwan
[4] Tunghai Univ, Dept Comp Sci & Informat Engn, Taichung 40704, Taiwan
[5] Changhua Christian Hosp, Dept Med Imaging, Changhua 500, Taiwan
关键词:
Vascularization index;
Flow index;
Vascularization-flow index;
Logistic regression analysis;
Neural network;
Support Vector Machine;
COMPUTER-AIDED DIAGNOSIS;
TEXTURE ANALYSIS;
ULTRASOUND;
CLASSIFICATION;
SONOGRAPHY;
FEATURES;
NODULES;
CANCER;
MASSES;
LESIONS;
D O I:
10.3348/kjr.2009.10.5.464
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
100231 [临床病理学];
100902 [航空航天医学];
摘要:
Objective: Logistic regression analysis (LRA), Support Vector Machine (SVM) and a neural network (NN) are commonly used statistical models in computer-aided diagnostic (CAD) systems for breast ultrasonography (US). The aim of this study was to clarify the diagnostic ability of the use of these statistical models for future applications of CAD systems, such as three-dimensional (3D) power Doppler imaging, vascularity evaluation and the differentiation of a solid mass. Materials and Methods: A database that contained 3D power Doppler imaging pairs of non-harmonic and tissue harmonic images for 97 benign and 86 malignant solid tumors was utilized. The virtual organ computer-aided analysis-imaging program was used to analyze the stored volumes of the 183 solid breast an SVM and NN were employed in comparative analyses for the tumors. LRA, characterization of benign and malignant solid breast masses from the database. Results: The values of area under receiver operating characteristic (ROC) curve, referred to as Az values for the use of non-harmonic 3D power Doppler US with LRA, SVM and NN were 0.9341, 0.9185 and 0.9086, respectively. The Az values for the use of harmonic 3D power Doppler US with LRA, SVM and NN 0.8979 and 0.9009, respectively. The Az values of six ROC curves were 0.9286, for the use of LRA, SVM and NN for non-harmonic or harmonic 3D power Doppler imaging were similar. Conclusion: The diagnostic performances of these three models (LRA, SVM and NN) are not different as demonstrated by ROC curve analysis. Depending on user emphasis for the use of ROC curve findings, the use of LRA appears to provide better sensitivity as compared to the other statistical models.
引用
收藏
页码:464 / 471
页数:8
相关论文