Practical implications of some recent studies in electrospray ionization fundamentals

被引:1118
作者
Cech, NB
Enke, CG
机构
[1] Univ New Mexico, Dept Chem, Albuquerque, NM 87131 USA
[2] Univ N Carolina, Dept Chem & Biochem, Greensboro, NC 27412 USA
关键词
ESI-MS; proton affinity; surface activity; solvent; stability; negative ion; detection limit;
D O I
10.1002/mas.10008
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In accomplishing successful electrospray ionization analyses, it is imperative to have an understanding of the effects of variables such as analyte structure, instrumental parameters, and solution composition. Here, we review some fundamental studies of the ESI process that tire relevant to these issues. We discuss how analyte chargeability and surface activity are related to ESI response, and how accessible parameters such as nonpolar surface area and reversed phase HPLC retention time call be used to predict relative ESI response. Also presented is a description of how derivitizing agents call be used to maximize or enable ESI response by improving the chargeability or hydrophobicity of ESI analytes. Limiting factors in the ESI Calibration curve are discussed. At high concentrations, these factors include droplet surf ice area and excess charge concentration, whereas at low concentrations ion transmission becomes an issue, and chemical interference call also be limiting. Stable and reproducible non-pneumatic ESI operation depends on the ability to balance a number of parameters, including applied voltage and solution surface tension, flow rate, and conductivity. V discuss how changing these parameters can shift the mode of ESI operation from stable to unstable, and how current-voltage curves can be used to characterize the mode of ESI operation. Finally. the characteristics of the ideal ESI solvent, including surface tension and conductivity requirements are discussed. Analysis in the positive Ion mode can be accomplished with acidified methanol/water solutions, but negative ion mode analysis necessitates special constituents that suppress corona discharge and facilitate the production of stable negative ions. (C) 2002 Wiley Periodicals. Inc..
引用
收藏
页码:362 / 387
页数:26
相关论文
共 138 条
[1]   Characterization of ginseng saponins using electrospray mass spectrometry and collision-induced dissociation experiments of metal-attachment ions [J].
Ackloo, SZ ;
Smith, RW ;
Terlouw, JK ;
McCarry, BE .
ANALYST, 2000, 125 (04) :591-597
[2]   Applications of mass spectrometry to food proteins and peptides [J].
Alomirah, HF ;
Alli, I ;
Konishi, Y .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (01) :1-21
[3]  
Amad MH, 2000, J MASS SPECTROM, V35, P784, DOI 10.1002/1096-9888(200007)35:7<784::AID-JMS17>3.0.CO
[4]  
2-Q
[5]  
AMAD MH, 2000, 48 C MASS SPECTR ALL
[6]  
[Anonymous], 1997, ELECTROSPRAY IONIZAT
[7]   ENHANCED SENSITIVITY FOR PEPTIDE-MAPPING WITH ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN THE PRESENCE OF SIGNAL SUPPRESSION DUE TO TRIFLUOROACETIC ACID-CONTAINING MOBILE PHASES [J].
APFFEL, A ;
FISCHER, S ;
GOLDBERG, G ;
GOODLEY, PC ;
KUHLMANN, FE .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :177-190
[8]   Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry [J].
Apffel, A ;
Chakel, JA ;
Fischer, S ;
Lichtenwalter, K ;
Hancock, WS .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1320-1325
[9]  
Apffel A, 1998, DEV BIOLOGICALS, V96, P11
[10]   High sensitivity analysis of neutral underivatized oligosaccharides by nanoelectrospray mass spectrometry [J].
Bahr, U ;
Pfenninger, A ;
Karas, M ;
Stahl, B .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4530-4535