Failure of an automated blood culture system to detect nonfermentative gram-negative bacteria

被引:35
作者
Klaerner, HG
Eschenbach, U
Kamereck, K
Lehn, N
Wagner, H
Miethke, T
机构
[1] Tech Univ Munich, Inst Med Microbiol Immunol & Hyg, D-81675 Munich, Germany
[2] Univ Regensburg, Inst Med Microbiol & Hyg, D-93053 Regensburg, Germany
关键词
D O I
10.1128/JCM.38.3.1036-1041.2000
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
During a 1-year study we observed that both aerobic and anaerobic blood culture bottles from patients were negative by the BacT/Alert system during a 7-day incubation period, However, upon subcultivation of negative bottles, growth of Pseudomonas aeruginosa was detectable, In an attempt to explain this observation, aerobic BacT/Alert Fan bottles were seeded with a defined inoculum (0.5 McFarland standard; 1 ml) of Escherichia coli, Klebsiella pneumoniae, Serratia marcescens, P. aeruginosa, Stenotrophomonas maltophilia, or Acinetobacter baumannii, Half of the inoculated bottles were loaded into the BacT/Alert system immediately, and the remainder were preincubated for 4, 8, 16, and 24 h at 36 degrees C. With preincubation all bottles seeded with the Enterobacteriaceae signaled positive during the next 1.5 h, Organisms in bottles seeded with the nonfermentative species P. aeruginosa and A. baumannii remained undetected by the BacT/Alert system for 7 days. S. maltophilia was detected if the preincubation time was equal or less than 8 h. Without preincubation all bottles seeded,vith the Enterobacteriaceae or nonfermentative species signaled positive. Since nonfermentative species seem to enter a state of bacteriostasis within the preincubation period, we reasoned that an unknown factor is consumed. Accordingly, a smaller inoculum should allow the detection of nonfermentative species, even after preincubation, and serial dilutions of P. aeruginosa were detected in preincubated bottles. In this case preincubated bottles signaled positive faster than bottles without preincubation. We conclude that all bottles from clinical settings should be subcultured prior to loading to avoid false negatives. An alternative may be preincubation at room temperature.
引用
收藏
页码:1036 / 1041
页数:6
相关论文
共 8 条
[1]   Microbiological factors influencing the outcome of nosocomial bloodstream infections: A 6-year validated, population-based model [J].
Pittet, D ;
Li, N ;
Woolson, RF ;
Wenzel, RP .
CLINICAL INFECTIOUS DISEASES, 1997, 24 (06) :1068-1078
[2]   VALUE OF TERMINAL SUBCULTURES FOR BLOOD CULTURES MONITORED BY BACTEC-9240 [J].
SHIGEI, JT ;
SHIMABUKURO, JA ;
PEZZLO, MT ;
DELAMAZA, LM ;
PETERSON, EM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (05) :1385-1388
[3]   COMPARISON OF BACTEC-9240 AND BACT/ALERT BLOOD CULTURE SYSTEMS IN AN ADULT HOSPITAL [J].
SMITH, JA ;
BRYCE, EA ;
NGUIYEN, JH ;
ROBERTS, FJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (07) :1905-1908
[4]  
WASHINGTON JA, 1986, REV INFECT DIS, V8, P792
[5]  
Weinstein MP, 1997, CLIN INFECT DIS, V24, P584, DOI 10.1093/clind/24.4.584
[6]   Current blood culture methods and systems: Clinical concepts, technology, and interpretation of results [J].
Weinstein, MP .
CLINICAL INFECTIOUS DISEASES, 1996, 23 (01) :40-46
[7]   CLINICAL CORRELATIONS OF SERIAL QUANTITATIVE BLOOD CULTURES DETERMINED BY LYSIS-CENTRIFUGATION IN PATIENTS WITH PERSISTENT SEPTICEMIA [J].
WHIMBEY, E ;
WONG, B ;
KIEHN, TE ;
ARMSTRONG, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (06) :766-771
[8]   Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections [J].
Ziegler, R ;
Johnscher, I ;
Martus, P ;
Lenhardt, D ;
Just, HM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (03) :657-661