A 20-ml blood sample was collected from adult patients with suspected bloodstream infections and distributed equally into the four volume-controlled bottles of a blood culture set consisting of aerobic and anaerobic BACTEC Plus/F bottles and aerobic and anaerobic BacT/Alert FAN bottles. All bottles were incubated in their respective instruments for a standard 5-day protocol or until the instruments signalled positivity. Samples in all bottles with negative results by these instruments were terminally subcultured. A total of 8,390 blood culture sets were obtained during the study period, of which 4,402 (52.5%) met the study criteria. Of these, 946 (21.5%) were positive either by instrument signal or by additional terminal subculture of all negative bottles and yielded growth of microorganisms. Five hundred eighty-nine (13.4%) blood culture sets were considered to have recovered 663 clinically significant organisms. When both the BACTEC and the BacT/Alert systems were used, 465 positive sets were detected; BACTEC alone detected 52 positive sets and BacT/Alert alone detected 72 (P = 0.09). No differences were found between the two systems in microbial recovery rate from blood cultures obtained from patients on antibiotic therapy. Significantly more members of the family Enterobacteriaceae (P < 0.01) were detected from patients without antimicrobial therapy by BacT/Alert than by BACTEC. The false-negative rates were 0.20% for BACTEC and 0.32% for BacT/Alert. A significantly higher false-positive rate was found for BACTEC (P < 0.0001). Both systems were comparable for the time to detection of microorganisms. However, gram-positive bacteria were detected faster by BACTEC and Enterobacteriaceae were detected faster on average by BacT/Alert. We concluded that both systems are comparable in their abilities to recover aerobic and anaerobic organisms from blood cultures and a terminal subculture might not be necessary for either of the two systems. The increased positivity rate when using an anaerobic bottle in a two-bottle blood culture set is due to the additional blood volume rather than to the use of an anaerobic medium.
引用
收藏
页码:657 / 661
页数:5
相关论文
共 20 条
[1]  
AUCKENTHALER R, 1994, EUR C CLIN MICR INF
[2]  
FONTANALS D, 1996, 7 NAT C SPAN SOC INF
[3]   TIME TO DETECTION OF POSITIVE BACT ALERT BLOOD CULTURES AND LACK OF NEED FOR ROUTINE SUBCULTURE OF 5-DAY TO 7-DAY NEGATIVE CULTURES [J].
HARDY, DJ ;
HULBERT, BB ;
MIGNEAULT, PC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (10) :2743-2745
[4]   Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia [J].
Jorgensen, JH ;
Mirrett, S ;
McDonald, LC ;
Murray, PR ;
Weinstein, MP ;
Fune, J ;
Trippy, CW ;
Masterson, M ;
Reller, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (01) :53-58
[5]   RATIONALE FOR SELECTIVE USE OF ANAEROBIC BLOOD CULTURES [J].
MORRIS, AJ ;
WILSON, ML ;
MIRRETT, S ;
RELLER, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (08) :2110-2113
[6]   Microbiological factors influencing the outcome of nosocomial bloodstream infections: A 6-year validated, population-based model [J].
Pittet, D ;
Li, N ;
Woolson, RF ;
Wenzel, RP .
CLINICAL INFECTIOUS DISEASES, 1997, 24 (06) :1068-1078
[7]  
PITTET D, 1997, PREVENTION CONTROL N
[8]   CONTROLLED CLINICAL-EVALUATION OF BACTEC PLUS AEROBIC/F AND BACT/ALERT AEROBIC FAN BOTTLES FOR DETECTION OF BLOOD-STREAM INFECTIONS [J].
POHLMAN, JK ;
KIRKLEY, BA ;
EASLEY, KA ;
BASILLE, BA ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (11) :2856-2858
[9]  
Riest Gunther, 1997, Clin Microbiol Infect, V3, P345, DOI 10.1111/j.1469-0691.1997.tb00624.x
[10]  
ROBERTS FJ, 1991, REV INFECT DIS, V13, P34