Low-intensity ultrasound increases endothelial cell nitric oxide synthase activity and nitric oxide synthesis

被引:88
作者
Altland, OD
Dalecki, D
Suchkova, VN
Francis, CW
机构
[1] Univ Rochester, Sch Med & Dent, Rochester Ctr Biomed Ultrasound, Rochester, NY USA
[2] Univ Rochester, Sch Med & Dent, Dept Biomed Engn, Rochester, NY USA
[3] Univ Rochester, Sch Med & Dent, Dept Med, Hematol Oncol Unit, Rochester, NY 14642 USA
关键词
endothelial cells; nitric oxide; nitric oxide synthase; ultrasound;
D O I
10.1111/j.1538-7836.2004.00655.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Low-intensity ultrasound (US) increases tissue perfusion in ischemic muscle through a nitric oxide (NO)dependent mechanism. We have developed a model to expose endothelial cells to well-characterized acoustic fields in vitro and investigate the physical and biological mechanisms involved. Human umbilical vein endothelial cells (HUVEC) or bovine aortic endothelial cells (BAEC) were grown in tissue culture plates suspended in a temperature-controlled water bath and exposed to US. Exposure to 27 kHz continuous wave US at 0.25 W cm(-2) for 10 min increased HUVEC media NO by 102 +/- 19% (P < 0.05) and BAEC by 117 +/- 23% (P < 0.01). Endothelial cell NO synthase activity increased by 27 +/- 24% in HUVEC and by 32 +/- 16% in BAEC (P < 0.05 for each). The cell response was rapid with a significant increase in NO synthesis by 10 s and a maximum increase after exposure for 1 min. By 30 min post-exposure NO synthesis declined to baseline, indicating that the response was transient. Unexpectedly, pulsing at a 10% duty Cycle resulted in a 46% increase in NO synthesis over the response seen with continuous wave US, resulting in an increase of 147 +/- 18%. Cells responded to very low intensity US, with a significant increase at 0.075 W cm(-2) (p < 0.01) and a maximum response at 0.125 W cm-2. US caused minor reversible changes in cell morphology but did not alter proliferative capacity, indicating absence of injury. We conclude that exposure of endothelial cells to low-intensity, low-frequency US increases NO synthase activity and NO production, which could be used to induce vasodilatation experimentally or therapeutically.
引用
收藏
页码:637 / 643
页数:7
相关论文
共 42 条
[1]   Nitric oxide synthases: structure, function and inhibition [J].
Alderton, WK ;
Cooper, CE ;
Knowles, RG .
BIOCHEMICAL JOURNAL, 2001, 357 (03) :593-615
[2]   CYCLIC STRAIN UP-REGULATES NITRIC-OXIDE SYNTHASE IN CULTURED BOVINE AORTIC ENDOTHELIAL-CELLS [J].
AWOLESI, MA ;
SESSA, WC ;
SUMPIO, BE .
JOURNAL OF CLINICAL INVESTIGATION, 1995, 96 (03) :1449-1454
[3]   Transcranial ultrasound-improved thrombolysis: Diagnostic vs. therapeutic ultrasound [J].
Behrens, S ;
Spengos, K ;
Daffertshofer, M ;
Schroeck, H ;
Dempfle, CE ;
Hennerici, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (12) :1683-1689
[4]  
BLINC A, 1993, BLOOD, V81, P2636
[5]   Phosphorylation of endothelial nitric oxide synthase in response to fluid shear stress [J].
Corson, MA ;
James, NL ;
Latta, SE ;
Nerem, RM ;
Berk, BC ;
Harrison, DG .
CIRCULATION RESEARCH, 1996, 79 (05) :984-991
[6]   FLOW-MEDIATED ENDOTHELIAL MECHANOTRANSDUCTION [J].
DAVIES, PF .
PHYSIOLOGICAL REVIEWS, 1995, 75 (03) :519-560
[7]   Activation of nitric oxide synthase in endothelial cells by Akt-dependent phosphorylation [J].
Dimmeler, S ;
Fleming, I ;
Fisslthaler, B ;
Hermann, C ;
Busse, R ;
Zeiher, AM .
NATURE, 1999, 399 (6736) :601-605
[8]  
Emerson GG, 2000, CIRC RES, V87, P474
[9]   ULTRASONIC ENERGY - EFFECTS ON VASCULAR FUNCTION AND INTEGRITY [J].
FISCHELL, TA ;
ABBAS, MA ;
GRANT, GW ;
SIEGEL, RJ .
CIRCULATION, 1991, 84 (04) :1783-1795
[10]  
Fisslthaler B, 2000, ACTA PHYSIOL SCAND, V168, P81