Development of a liquid chromatography-tandem mass spectrometric method for the determination of methamphetamine and amphetamine using small volumes of rat serum

被引:42
作者
Hendrickson, HP [1 ]
Milesi-Hallé, A [1 ]
Laurenzana, EM [1 ]
Owens, SM [1 ]
机构
[1] Univ Arkansas Med Sci, Dept Pharmacol & Toxicol, Little Rock, AR 72205 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 806卷 / 02期
关键词
methamphetamine; amphetamine;
D O I
10.1016/j.jchromb.2004.03.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this paper was to develop LC/MS/MS methodology for the determination of methamphetamine (METH) and amphetamine (AMP) using low microliter volumes (20-150 mul) of rat serum and demonstrate the use of this method for the study of serum pharmacokinetics in the rat. The analytes were extracted from rat serum using solid-phase extraction followed by an isocratic separation on a narrow-bore Hypersil C-18 column. Lower limits of quantitation for METH and AMP were 0.3 ng/ml using positive ion electrospray tandem mass spectrometry. The accuracy of the method was within 20% of the actual values over a wide range of serum concentrations. The within-day and between-day precision was better than 20% (R.S.D.). Ion-suppression matrix effects on electrospray ionization were evaluated for extracted rat serum. The LC/MS/MS method was further validated by comparing serum concentrations of METH and AMP to serum concentrations previously determined using an LC/[H-3]-METH assay with radiochemical detection. Finally, the LC/MS/MS method was used to study the pharmacokinetics of METH and AMP after a 1 mg/kg intravenous bolus dose of METH to female Sprague-Dawley rats. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 23 条
  • [1] Analysis of underivatized amphetamines and related phenethylamines with high-performance liquid chromatography -: Atmospheric pressure chemical ionization mass spectrometry
    Bogusz, MJ
    Krüger, KD
    Maier, RD
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (02) : 77 - 84
  • [2] Pharmacodynamic mechanisms of monoclonal antibody-based antagonism of (+)-methamphetamine in rats
    Byrnes-Blake, KA
    Laurenzana, EM
    Carroll, FI
    Abraham, P
    Gentry, WB
    Landes, RD
    Owens, SM
    [J]. EUROPEAN JOURNAL OF PHARMACOLOGY, 2003, 461 (2-3) : 119 - 128
  • [3] Cho AK, 2001, SYNAPSE, V39, P161, DOI 10.1002/1098-2396(200102)39:2<161::AID-SYN7>3.0.CO
  • [4] 2-E
  • [5] COOK CE, 1993, DRUG METAB DISPOS, V21, P717
  • [6] HAYAKAWA K, 1993, BIOL PHARM BULL, V16, P817
  • [7] DETERMINATION OF METHAMPHETAMINE, AMPHETAMINE AND PIPERIDINE IN HUMAN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION
    HAYAKAWA, K
    IMAIZUMI, N
    ISHIKURA, H
    MINOGAWA, E
    TAKAYAMA, N
    KOBAYASHI, H
    MIYAZAKI, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 515 : 459 - 466
  • [8] Increased plasma concentration and brain penetration of methamphetamine in behaviorally sensitized rats
    Kitaichi, K
    Morishita, Y
    Doi, Y
    Ueyama, J
    Matsushima, M
    Zhao, YL
    Takagi, K
    Hasegawa, T
    [J]. EUROPEAN JOURNAL OF PHARMACOLOGY, 2003, 464 (01) : 39 - 48
  • [9] Progress of liquid chromatography-mass spectrometry in clinical and forensic toxicology
    Marquet, P
    [J]. THERAPEUTIC DRUG MONITORING, 2002, 24 (02) : 255 - 276
  • [10] Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    Matuszewski, BK
    Constanzer, ML
    Chavez-Eng, CM
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (13) : 3019 - 3030