Determination of cholesterol in atherosclerotic plaques using near infrared diffuse reflection spectroscopy

被引:58
作者
Jaross, W
Neumeister, V
Lattke, P
Schuh, D
机构
[1] Tech Univ Dresden, Fac Med, Inst Clin Chem & Lab Med, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Fac Med, Inst Pathol, D-8027 Dresden, Germany
关键词
arteriosclerosis; aorta; cholesterol; plaques; spectroscopy;
D O I
10.1016/S0021-9150(99)00203-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this investigation was to examine whether near infrared diffuse reflection spectroscopy is an acceptable tool for the determination of cholesterol content in atherosclerotic plaques. Using an FT-spectrophotometer (lambda = 1000-2500 nm) and fiberoptic systems (d = 4 mm), the cholesterol content could be determined in mixtures of the primary compounds of the aortic wall with acceptable precision. Considering the inhomogeneous distribution of cholesterol and cholesterol esters in atherosclerotic plaques the determination of total cholesterol using this method is of acceptable efficacy, even though the calibration procedure did not reflect the composition correctly. Using an energy dose of less than 100 mW/cm(2) to avoid damage to endothelial cells, arterial tissue of about 170-200 um thickness attenuates the reflected NIRS signal by up to 50%. Cholesterol levels could be determined accurately in atherosclerotic lesions in human aortic specimens obtained by autopsy. The correlation coefficient between the NIRS results and those of HPLC analysis calculated in the investigation of 82 different areas of 18 human aortic specimens was 0.926 (y = 0.869x +/- 0.771, external validation). Acceptable results were also achieved by means of a coronary-catheterlike fiberoptic strand (d = 1 mm), despite the worsened signal/noise ratio. The results show that the development of a coronary catheter using NIRS appears to be possible in principle. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:327 / 337
页数:11
相关论文
共 36 条
[1]  
[Anonymous], 1997, HEALTH PHYS, V73, P539
[2]  
ARAKI R, 1992, OXYGEN TRANSPORT TIS, V13, P155
[3]   INSITU OPTICAL HISTOCHEMISTRY OF HUMAN ARTERY USING NEAR-INFRARED FOURIER-TRANSFORM RAMAN-SPECTROSCOPY [J].
BARAGA, JJ ;
FELD, MS ;
RAVA, RP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (08) :3473-3477
[4]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[5]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING PARTIAL LEAST-SQUARES AND ARTIFICIAL NEURAL NETWORKS BASED ON MIDINFRARED SPECTROSCOPY [J].
BHANDARE, P ;
MENDELSON, Y ;
PEURA, RA ;
JANATSCH, G ;
KRUSEJARRES, JD ;
MARBACH, R ;
HEISE, HM .
APPLIED SPECTROSCOPY, 1993, 47 (08) :1214-1221
[6]  
Brennan JF, 1997, CIRCULATION, V96, P99
[7]   Thermal detection of cellular infiltrates in living atherosclerotic plaques: Possible implications for plaque rupture and thrombosis [J].
Casscells, W ;
Hathorn, B ;
David, M ;
Krabach, T ;
Vaughn, WK ;
McAllister, HA ;
Bearman, G ;
Willerson, JT .
LANCET, 1996, 347 (9013) :1447-1449
[8]   NEAR-IR IMAGING OF ATHEROMAS IN LIVING ARTERIAL TISSUE [J].
CASSIS, LA ;
LODDER, RA .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1247-1256
[9]   BODY-COMPOSITION ASSESSMENT [J].
DAVIES, PSW .
ARCHIVES OF DISEASE IN CHILDHOOD, 1993, 69 (03) :337-338
[10]   Biological and medical applications of near-infrared spectrometry [J].
Dempsey, RJ ;
Davis, DG ;
Buice, RG ;
Lodder, RA .
APPLIED SPECTROSCOPY, 1996, 50 (02) :A18-A34