Microporous membrane liquid-liquid extraction technique combined with gas chromatography mass spectrometry for the determination of organotin compounds

被引:30
作者
Ndungu, K [1 ]
Mathiasson, L [1 ]
机构
[1] Univ Lund, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
butyltin; phenyltin; microporous membrane; sodium tetraethylborate; natural waters; gas chromatography-mass spectrometry; liquid-liquid extraction;
D O I
10.1016/S0003-2670(99)00702-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sample clean-up and enrichment method based on microporous membrane liquid-liquid extraction (MMLLE) in a how system was developed for the determination of organotin (CYT) compounds in complex matrices. Ionic OT compounds in the aqueous sample were derivatised off-line using sodium tetraethylborate (NABEt(4)). Then, the sample solution was pumped through the donor channel of a membrane device holding a hydrophobic microporous membrane. The pores of the membrane and acceptor channel of the device were filled with an organic solvent (isooctane). OT species were extracted into the stagnant acceptor phase. The OT species in these MMLLE extracts were separated and analysed by gas chromatography-mass spectrometry (GC-MS) in the selected ion monitoring mode. The detection limits (LODs) (3 x noise) of the method for a 30 mi water sample ranged between 13 and 265 ng l(-1) for various OT species. (C)2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:319 / 328
页数:10
相关论文
共 38 条
[1]   Analytical procedures for the determination of organotin compounds in sediment and biota: a critical review [J].
Abalos, M ;
Bayona, JM ;
Compano, R ;
Granados, M ;
Leal, C ;
Prat, MD .
JOURNAL OF CHROMATOGRAPHY A, 1997, 788 (1-2) :1-49
[2]   Aqueous speciation and 1-octanol-water partitioning of tributyl- and triphenyltin: Effect of pH and ion composition [J].
Arnold, CG ;
Weidenhaupt, A ;
David, MM ;
Muller, SR ;
Haderlein, SB ;
Schwarzenbach, RP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (09) :2596-2602
[3]  
Attar KM, 1996, APPL ORGANOMET CHEM, V10, P317, DOI 10.1002/(SICI)1099-0739(199606)10:5<317::AID-AOC485>3.3.CO
[4]  
2-W
[6]   CONTAINER ADSORPTION OF TRIBUTYLTIN (TBT) COMPOUNDS - IMPLICATIONS FOR ENVIRONMENTAL-ANALYSIS [J].
CARTER, RJ ;
TUROCZY, NJ ;
BOND, AM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (05) :615-617
[7]   RAPID SENSITIVE SPECIATION ANALYSIS OF BUTYLTIN AND PHENYLTIN COMPOUNDS IN WATER BY CAPILLARY GAS-CHROMATOGRAPHY ATOMIC-EMISSION SPECTROMETRY (GC-AES) AFTER IN-SITU ETHYLATION AND IN-LINER PRECONCENTRATION [J].
CEULEMANS, M ;
LOBINSKI, R ;
DIRKX, WMR ;
ADAMS, FC .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (6-7) :256-262
[8]   Supported liquid membrane enrichment using an organophosphorus extractant for analytical trace metal determinations in river waters [J].
Djane, NK ;
Ndungu, K ;
Malcus, F ;
Johansson, G ;
Mathiasson, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (7-8) :822-827
[9]   Chromium speciation in natural waters using serially connected supported liquid membranes [J].
Djane, NK ;
Ndung'u, K ;
Johnsson, C ;
Sartz, H ;
Tornstrom, T ;
Mathiasson, L .
TALANTA, 1999, 48 (05) :1121-1132
[10]   Supported liquid membrane enrichment combined with atomic absorption spectrometry for the determination of lead in urine [J].
Djane, NK ;
Bergdahl, IA ;
Ndungu, K ;
Schutz, A ;
Johansson, G ;
Mathiasson, L .
ANALYST, 1997, 122 (10) :1073-1077