Electrospray ionization mass spectrometric analysis of nucleic acids using high-throughput on-line desalting

被引:22
作者
Fountain, KJ [1 ]
Gilar, M [1 ]
Gebler, JC [1 ]
机构
[1] Waters Corp, Life Sci Chem, Milford, MA 01757 USA
关键词
D O I
10.1002/rcm.1481
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A rapid on-line desalting method utilizing ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC) was employed in tandem with negative electrospray ionization mass spectrometry (ESI-MS) for the routine analysis of nucleic acids. Desalting was performed on a short 10 x 2.1 mm guard column packed with 3.5 mum C-18 sorbent. The HPLC system was connected in-line to an orthogonal ESI-TOF mass spectrometer via a six-port, two-position switching valve, allowing desalting followed by mass analysis of nucleic acids. Duty cycle times for the method were as low as 1.5 min per sample. This allowed for the analysis of approximately 950 samples per 24-h time period, which is suitable for medium- to high-throughput applications. Average mass accuracy was determined to be 80 ppm for oligonucleotides up to 110 mer in length with external calibration. The method was utilized for synthetic oligonucleotide quality control and analysis of DNA genotyping fragments. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1295 / 1302
页数:8
相关论文
共 33 条
[1]
Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry [J].
Apffel, A ;
Chakel, JA ;
Fischer, S ;
Lichtenwalter, K ;
Hancock, WS .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1320-1325
[2]
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry as a rapid quality control method in oligonucleotide synthesis [J].
Ball, RW ;
Packman, LC .
ANALYTICAL BIOCHEMISTRY, 1997, 246 (02) :185-194
[3]
Single nucleotide polymorphism genotyping by on-line liquid chromatography-mass spectrometry in forensic science of the Y-chromosomal locus M9 [J].
Berger, B ;
Hölzl, G ;
Oberacher, H ;
Niederstätter, H ;
Huber, CG ;
Parson, W .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 782 (1-2) :89-97
[4]
ANALYSIS OF OLIGONUCLEOTIDES USING COUPLED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY [J].
BLEICHER, K ;
BAYER, E .
CHROMATOGRAPHIA, 1994, 39 (7-8) :405-408
[5]
Bruenner BA, 1996, RAPID COMMUN MASS SP, V10, P1797
[6]
De Bellis G, 2000, RAPID COMMUN MASS SP, V14, P243, DOI 10.1002/(SICI)1097-0231(20000229)14:4<243::AID-RCM870>3.0.CO
[7]
2-F
[8]
Analysis of native and chemically modified oligonucleotides by tandem ion-pair reversed-phase high-performance liquid chromatography/electrospray ionization mass spectrometry [J].
Fountain, KJ ;
Gilar, M ;
Gebler, JC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (07) :646-653
[9]
On-line HPLC electrospray mass spectrometry of phosphorothioate oligonucleotide metabolites [J].
Gaus, HJ ;
Owens, SR ;
Winniman, M ;
Cooper, S ;
Cummins, LL .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :313-319
[10]
High-throughput biopolymer desalting by solid-phase extraction prior to mass spectrometric analysis [J].
Gilar, M ;
Belenky, A ;
Wang, BH .
JOURNAL OF CHROMATOGRAPHY A, 2001, 921 (01) :3-13