Time-resolved fluorescent imaging of glucose

被引:36
作者
Schäferling, M [1 ]
Wu, M [1 ]
Wolfbeis, OS [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
optical sensor; time-resolved fluorescence imaging; europium tetracycline; glucose sensor;
D O I
10.1023/B:JOFL.0000039343.02843.12
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A method for the fluorescent imaging of glucose is described that is based on the detection of enzymatically produced hydrogen peroxide, using the europium(III) tetracycline complex as the fluorescent probe incorporated into a hydrophilic polymer layer. Coadsorption of glucose oxidase (GOx) makes these sensor layers respond to the hydrogen peroxide produced by the GOx-assisted oxidation of glucose. The hydrogel layers are integrated into a 96-microwell plate for a parallel and simultaneous detection of various samples. Glucose is visualized by means of time resolved luminescence lifetime imaging. Unlike in previous methods, the determination of H2O2 does not require the addition of peroxidase or a catalyst to form a fluorescent product. The lifetime-based images obtained are compared with conventional fluorescence intensity-based methods with respect to sensitivity and the dynamic range of the sensor layer. The main advantages provided by this sensing scheme for H2O2 include reversibility, applicability at neutral pH, and the straightforwardness of the transducer system and the imaging device.
引用
收藏
页码:561 / 568
页数:8
相关论文
共 42 条
[1]
Anderson RE, 2002, METHOD ENZYMOL, V352, P482
[2]
Andreeff M., 1999, INTRO FLUORESCENCE I
[3]
Effects of light fractionation and different fluence rates on photodynamic therapy with 5-aminolaevulinic acid in vivo [J].
Babillas, P ;
Schacht, V ;
Liebsch, G ;
Wolfbeis, OS ;
Landthaler, M ;
Szeirinies, RM ;
Abels, C .
BRITISH JOURNAL OF CANCER, 2003, 88 (09) :1462-1469
[4]
Evaluation of two synthetic glucose probes for fluorescence-lifetime-based sensing [J].
DiCesare, N ;
Lakowicz, JR .
ANALYTICAL BIOCHEMISTRY, 2001, 294 (02) :154-160
[5]
Habermüller K, 2000, ELECTROANAL, V12, P1383, DOI 10.1002/1521-4109(200011)12:17<1383::AID-ELAN1383>3.0.CO
[6]
2-0
[7]
HALL EA, 1990, BIOSENSORS, P253
[8]
Two-photon fluorescence lifetime imaging of the skin stratum corneum pH gradient [J].
Hanson, KM ;
Behne, MJ ;
Barry, NP ;
Mauro, TM ;
Gratton, E ;
Clegg, RM .
BIOPHYSICAL JOURNAL, 2002, 83 (03) :1682-1690
[9]
Lifetime imaging of luminescent oxygen sensors based on all-solid-state technology [J].
Hartmann, P ;
Ziegler, W .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4512-4514
[10]
Oxygen flux fluorescence lifetime imaging [J].
Hartmann, P ;
Ziegler, W ;
Holst, G ;
Lubbers, DW .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :110-115