Three-dimensional localization of ultrasmall immuno-gold labels by HAADF-STEM tomography

被引:39
作者
Ziese, U
Kübel, C
Verkleij, AJ
Koster, AJ [1 ]
机构
[1] Univ Utrecht, NL-3584 CH Utrecht, Netherlands
[2] FEI Co, Applicat Lab, NL-5600 KA Eindhoven, Netherlands
关键词
3D reconstruction; electron tomography; high angular annular dark-field-scanning TEM; tilt series; ultrasmall immuno-gold labels;
D O I
10.1016/S1047-8477(02)00018-7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The localization of scarce antigens in thin sections of biological material can be accomplished by pre-embedment labeling with ultrasmall immuno-gold labels. Moreover, with this method, labeling is not restricted to the section surface but occurs throughout the section volume. Thus, when combined with electron tomography, antigens can be localized in three dimensions in relation to the 3D (three-dimensional) ultrastructure of the cell. However, for visualization in a transmission electron microscope, these labels need to be enlarged by silver or gold enhancement. The increase in particle size reduces the resolution of the antigen detection and the large particles obscure ultrastructural details in the tomogram. In this paper we show for the first time that these problems can be avoided and that ultrasmall gold labels can be localized in three dimensions without the need for gold or silver enhancement by using HAADF-STEM (high angular annular dark-field-scanning transmission electron microscopy) tomography. This method allowed us to three-dimensionally localize Aurion ultrasmall goat anti-rabbit immuno-gold labels on sections of Epon-embedded, osmium-uranium-lead-stained biological material. Calculations show that a 3D reconstruction obtained from HAADF-STEM projection images can be spatially aligned to one obtained from transmission electron microscopy (TEM) projections with subpixel accuracy. We conclude that it is possible to combine the high-fidelity structural information of TEM tomograms with the ultrasmall label localization ability of HAADF-STEM tomograms. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:58 / 62
页数:5
相关论文
共 22 条
[1]   An auto-tuning method for focusing and astigmatism correction in HAADF-STEM, based on the image contrast transfer function [J].
Baba, N ;
Terayama, K ;
Yoshimizu, T ;
Ichise, N ;
Tanaka, N .
JOURNAL OF ELECTRON MICROSCOPY, 2001, 50 (03) :163-176
[2]   APPLICATIONS OF MEDIUM-VOLTAGE STEM FOR THE 3-D STUDY OF ORGANELLES WITHIN VERY THICK SECTIONS [J].
BEORCHIA, A ;
HELIOT, L ;
MENAGER, M ;
KAPLAN, H ;
PLOTON, D .
JOURNAL OF MICROSCOPY, 1993, 170 :247-258
[4]   Toward fully automated high-resolution electron tomography [J].
Fung, JC ;
Liu, WP ;
deRuijter, WJ ;
Chen, H ;
Abbey, CK ;
Sedat, JW ;
Agard, DA .
JOURNAL OF STRUCTURAL BIOLOGY, 1996, 116 (01) :181-189
[5]   New frontiers in gold labeling [J].
Hainfeld, JF ;
Powell, RD .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2000, 48 (04) :471-480
[6]  
Hainfeld JF, 1999, P 57 ANN M MICR SOC, P486
[7]  
HAINFELD JF, 1990, P 12 INT C EL MICR, P954
[8]   How hearing happens [J].
Hudspeth, AJ .
NEURON, 1997, 19 (05) :947-950
[9]  
Humbel BM, 1998, MICROSC RES TECHNIQ, V42, P43, DOI 10.1002/(SICI)1097-0029(19980701)42:1<43::AID-JEMT6>3.0.CO
[10]  
2-S