Aptamer biosensor for lable-free detection of human immunoglobulin E based on surface plasmon resonance

被引:61
作者
Kim, Yun Hwa [1 ]
Kim, Jun Pyo [1 ]
Han, Se Jong [1 ]
Sim, Sang Jun [1 ]
机构
[1] Sungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South Korea
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2009年 / 139卷 / 02期
关键词
Immunoglobulin E (IgE); Surface plasmon resonance (SPR); Aptamer; Self-assembled monolayer (SAM); ALLERGY;
D O I
10.1016/j.snb.2009.03.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aptasensor, an aptamer-based sensor for non-labeled detection of human immunoglobulin E (IgE), was developed using Surface plasmon resonance (SPR). Various oligo(ethylene glycol) mixtures of different molar ratios of EG(6)-COOH and EG(3)-OH were used for the construction of self-assembled monolayers (SAM). Direct assays and modified sandwich assays over a 1.0nM anti-IgE, aptamer-immobilized, gold chip, consisting of a 1:3 molar ratio of EG(6)-COOH:EG(3)-OH SAM, were investigated for real-time IgE detection. The linear ranges for both were 1.0-1000 ng/mL and the lowest amounts of detectable analytes in the samples were 3.44 and 2.07 ng/mL for direct and modified sandwich assays, respectively. These results for IgE detection Suggest that the aptamer offers the possibility of a simple and realistic biosensor platform based oil a SAM-fabricated SPR system. Furthermore, as an optic-biosensor, an SPR aptasensor Could be used for the diagnosis of allergies. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:471 / 475
页数:5
相关论文
共 21 条
[1]  
Binh N., 2007, METHODS, V42, P150
[2]   Effects of space flights on human allergic status (IgE-mediated sensitivity) [J].
Buravkova, L. B. ;
Rykova, M. P. ;
Gertsik, Y. G. ;
Antropova, E. N. .
ACTA ASTRONAUTICA, 2007, 60 (4-7) :254-258
[3]   A strategy for sensitivity and specificity enhancements in prostate specific antigen-α1-antichymotrypsin detection based on surface plasmon resonance [J].
Cao, C ;
Kim, JP ;
Kim, BW ;
Chae, H ;
Yoon, HC ;
Yang, SS ;
Sim, SJ .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (11) :2106-2113
[4]  
EUN JC, 2006, ANAL CHIM ACTA, V564, P82
[5]   Complement and Fc-receptors in regulation of the antibody response [J].
Heyman, B .
IMMUNOLOGY LETTERS, 1996, 54 (2-3) :195-199
[6]  
HIJIRI H, 2008, SENSORS, V8, P1090
[7]   Evidence for two independent distributions of serum immunoglobulin E in atopic families: Cognate and non-cognate IgE [J].
Jackola, DR ;
Blumenthal, MN ;
Rosenberg, A .
HUMAN IMMUNOLOGY, 2004, 65 (01) :20-30
[8]  
KING CL, 1991, J IMMUNOL, V146, P1478
[9]   An aptamer-based quartz crystal protein biosensor [J].
Liss, M ;
Petersen, B ;
Wolf, H ;
Prohaska, E .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4488-4495
[10]   Label-free protein biosensor based on aptamer-modified carbon nanotube field-effect transistors [J].
Maehashi, Kenzo ;
Katsura, Taiji ;
Kerman, Kagan ;
Takamura, Yuzuru ;
Matsumoto, Kazuhiko ;
Tamiya, Eiichi .
ANALYTICAL CHEMISTRY, 2007, 79 (02) :782-787