A strategy for sensitivity and specificity enhancements in prostate specific antigen-α1-antichymotrypsin detection based on surface plasmon resonance

被引:125
作者
Cao, C
Kim, JP
Kim, BW
Chae, H
Yoon, HC
Yang, SS
Sim, SJ [1 ]
机构
[1] Sungkyunkwan Univ, Dept Chem Engn, Suwon 440746, South Korea
[2] Ajou Univ, Dept Biotechnol, Suwon 443749, South Korea
[3] Ajou Univ, Sch Elect & Comp Engn, Suwon 443749, South Korea
关键词
prostate specific antigen; surface plasmon resonance; enhancement; oligo(ethylene glycol); biotinylation; self-assembled monolayer;
D O I
10.1016/j.bios.2005.10.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A biochip based on surface plasmon resonance was fabricated to detect prostate specific antigen-alpha(1)-antichymotrypsin (PSA-ACT complex) in both HBS buffer and human serum. To reduce non-specific binding and steric hindrance effect, the chemical surface of the sensor chips was constructed by using various oligo(ethylene glycol) mixtures of different molar ratios of HS(CH2)(11)(OCH2CH2)(6)OCH2COOH and HS(CH2)(11)(OCH2CH2)(3)OH. The self-assembled monolayers were biotinylated to facilitate the immobilization of streptavidin. Using the chip surfaces, PSA-ACT complex in HBS buffer and human serum was detected at 20.7 and 47.5 ng/ml by primary immunoresponse, respectively. However, the limit of detection could be simply enhanced by a sandwich strategy to improve the sensitivity and specificity of the immunoassay. An intact PSA polyclonal antibody was used as an amplifying agent in the strategy. As a result, PSA-ACT complex concentrations as low as 10.2 and 18.1 ng/ml were found in the HBS buffer and human serum sample, respectively. The result indicates that this approach could satisfy our goal without modifying the secondary interactant. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2106 / 2113
页数:8
相关论文
共 26 条
[1]  
ARMBRUSTER DA, 1993, CLIN CHEM, V39, P181
[2]   Protein adsorption to oligo(ethylene glycol) self-assembled monolayers: Experiments with fibrinogen, heparinized plasma, and serum [J].
Benesch, J ;
Svedhem, S ;
Svensson, SCT ;
Valiokas, R ;
Liedberg, B ;
Tengvall, P .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2001, 12 (06) :581-597
[3]   Preparation of mixed self-assembled monolayers (SAMs) that resist adsorption of proteins using the reaction of amines with a SAM that presents interchain carboxylic anhydride groups [J].
Chapman, RG ;
Ostuni, E ;
Yan, L ;
Whitesides, GM .
LANGMUIR, 2000, 16 (17) :6927-6936
[4]   Protein repellant silicone surfaces by covalent immobilization of poly(ethylene oxide) [J].
Chen, H ;
Zhang, Z ;
Chen, Y ;
Brook, MA ;
Sheardown, H .
BIOMATERIALS, 2005, 26 (15) :2391-2399
[5]   Real-time immunoassay of ferritin using surface plasmon resonance biosensor [J].
Cui, XQ ;
Yang, F ;
Sha, YF ;
Yang, XR .
TALANTA, 2003, 60 (01) :53-61
[6]   BIOSPECIFIC INTERACTION ANALYSIS USING SURFACE-PLASMON RESONANCE DETECTION APPLIED TO KINETIC, BINDING-SITE AND CONCENTRATION ANALYSIS [J].
FAGERSTAM, LG ;
FROSTELLKARLSSON, A ;
KARLSSON, R ;
PERSSON, B ;
RONNBERG, I .
JOURNAL OF CHROMATOGRAPHY, 1992, 597 (1-2) :397-410
[7]   Reduced nonspecific adsorption on covalently immobilized protein surfaces using poly(ethylene oxide) containing blocking agents [J].
Frederix, F ;
Bonroy, K ;
Reekmans, G ;
Laureyn, W ;
Campitelli, A ;
Abramov, MA ;
Dehaen, W ;
Maes, G .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 58 (01) :67-74
[8]   Direct kinetic assay of interactions between small peptides and immobilized antibodies using a surface plasmon resonance biosensor [J].
Gomes, P ;
Andreu, D .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 259 (1-2) :217-230
[9]   USE OF BIFUNCTIONAL BIOTINYL COMPOUNDS TO DETERMINE ARRANGEMENT OF SUBUNITS IN AVIDIN [J].
GREEN, NM ;
KONIECZNY, L ;
TOMS, EJ ;
VALENTINE, RC .
BIOCHEMICAL JOURNAL, 1971, 125 (03) :781-+
[10]   Competitive protein adsorption as observed by surface plasmon resonance [J].
Green, RJ ;
Davies, MC ;
Roberts, CJ ;
Tendler, SJB .
BIOMATERIALS, 1999, 20 (04) :385-391