Hypothermic machine preservation in liver transplantation revisited: Concepts and criteria in the new millennium

被引:56
作者
van der Plaats, A
t'Hart, NA
Verkerke, GJ
Leuvenink, HGD
Ploeg, RJ
Rakhorst, G
机构
[1] Univ Groningen, Dept Biomed Engn, NL-9713 AV Groningen, Netherlands
[2] Univ Groningen Hosp, Surg Res Lab, NL-9713 GZ Groningen, Netherlands
关键词
hypothermic machine perfusion; liver; University of Wisconsin solution; perfusion characteristics; oxygen demand;
D O I
10.1023/B:ABME.0000019181.18194.51
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To overcome the present shortage of liver donors by expansion of the existing donor pool and possibly lengthening of the storage time, hypothermic machine perfusion of the liver as a dynamic preservation method is revisited. The three most important aspects are defined to be the type of preservation solution, the characteristics of perfusion dynamics, and the oxygen supply. Reviewing hypothermic liver machine perfusion experiments, the University of Wisconsin machine preservation solution is the solution most used. It is also found that nothing conclusive can be said about the optimal perfusion characteristics, since either perfusion pressure or perfusion flow is reported. The best estimation is perfusion of the liver in a physiological manner, i.e. pulsatile arterial perfusion and continuous portal venous perfusion. The applied pressures could be chosen to be somewhat lower than physiological pressures to prevent possible endothelial cell damage. Oxygen supply is necessary to achieve optimal preservation of the liver. The minimal amount of partial oxygen pressure required is inversely related to the normalized flow. Incorporating these features in a system based on existing standard surgical and organ sharing procedures and which is able to work stand-alone for 24 It, weighing less than 23 kg, could successfully implement this technique into every day clinical practise.
引用
收藏
页码:623 / 631
页数:9
相关论文
共 74 条
[61]   SUCCESSFUL 48-HOUR PRESERVATION OF THE RAT-LIVER BY CONTINUOUS HYPOTHERMIC PERFUSION WITH HEMACCEL ISOTONIC CITRATE SOLUTION [J].
TAMAKI, T ;
KAMADA, N ;
WIGHT, DG ;
PEGG, DE .
TRANSPLANTATION, 1987, 43 (04) :468-471
[62]  
TESI RJ, 1993, TRANSPLANT P, V25, P901
[63]  
THART NA, 2002, TRANSPLANT REV, V16, P131
[64]   EXTENDED PRESERVATION OF HUMAN-LIVER GRAFTS WITH UW SOLUTION [J].
TODO, S ;
NERY, J ;
YANAGA, K ;
PODESTA, L ;
GORDON, RD ;
STARZL, TE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1989, 261 (05) :711-714
[65]  
Tojimbara T, 1997, Liver Transpl Surg, V3, P39, DOI 10.1002/lt.500030106
[66]  
Treska Vladislav, 2002, Ann Transplant, V7, P45
[67]   Comparison between nonpulsatile and pulsatile machine perfusion preservation in liver transplantation from non-heart-beating donors [J].
Uchiyama, M ;
Matsuno, N ;
Hama, K ;
Iwamoto, H ;
Narumi, Y ;
Kikuchi, K ;
Degawa, H ;
Kozaki, K ;
Kubota, K ;
Takeuchi, H ;
Sakurai, E ;
Asuwa, N ;
Hirano, SMT ;
Nagao, T .
TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) :936-938
[68]   Liver transplantation from non-heart-beating donors: Effect of machine perfusion preservation and pentoxifylline [J].
Uchiyama, M ;
Kozaki, K ;
Nemoto, T ;
Degawa, H ;
Matsuno, N ;
Kubota, K ;
Takeuchi, H ;
Sakurai, E ;
Kozaki, M ;
Ikeda, T ;
Asuwa, N ;
Masuda, S ;
Nagao, T .
TRANSPLANTATION PROCEEDINGS, 1998, 30 (07) :3798-3800
[69]  
VANDERPLAATS A, IN PRESS TRANSPL INT
[70]   SOME FUNCTIONAL PARAMETERS IN THE ISOLATED CALF LIVER AFTER HYPOTHERMIC PRESERVATION [J].
VLADOVICRELJA, T .
CRYOBIOLOGY, 1984, 21 (05) :511-520