Column performance and stability for high-speed vacuum-outlet GC of volatile organic compounds using atmospheric pressure air as carrier gas

被引:27
作者
Grall, AJ [1 ]
Sacks, RD [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac990573y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of lightweight, portable GC instrumentation is handicapped by the need for compressed carrier gas to drive the separation. The use of air as carrier gas eliminates the need for compressed gas tanks. If a vacuum pump is used to pull carrier gas and injected samples through the column, atmospheric pressure air can be used as carrier gas. Vacuum outlet operation also improves performance for high-speed separations by reducing detector dead time and by shifting optimal carrier gas velocity to higher values. Under vacuum outlet conditions using atmospheric pressure air as carrier gas, a 6-m-long, 0.25-mm-i.d. capillary column can generate similar to 12 500 theoretical plates, and a 12-m-long column can generate similar to 44 000 plates but with a 3-4-fold increase in separation time. The principal issues in column selection for highspeed GC with air as a carrier gas are efficiency and stability. Several bonded and nonbonded stationary phases were evaluated for use with air as carrier gas in the analysis of volatile organic compounds of interest in air-monitoring applications. These include dimethylpolysiloxane, 50% phenyl-50% methyl polysiloxane, 50% cycanopropylphenyl-50% methyl polysiloxane, trifluropropyl polysiloxane, poly(ethylene glycol), and dicyanoallyl polysiloxane (nonbonded). The dimethyl polysiloxane and the trifluropropyl polysiloxane columns showed good efficiency and no significant deterioration after 5 days of continuous operation with air as carrier gas. The 50% phenyl-50% methyl polysiloxane and the 50% cycanopropylphenyl-50% methyl polysiloxane columns showed poorer efficiency, and the poly(ethylene glycol) and dicyanoallyl polysiloxane columns showed excessive deterioration in air.
引用
收藏
页码:5199 / 5205
页数:7
相关论文
共 24 条
[1]   SILICON MICROMECHANICAL DEVICES [J].
ANGELL, JB ;
TERRY, SC ;
BARTH, PW .
SCIENTIFIC AMERICAN, 1983, 248 (04) :44-&
[2]   INCREASED SPEED OF ANALYSIS IN DIRECTLY COUPLED GAS CHROMATOGRAPHY-MASS SPECTROMETRY SYSTEMS - CAPILLARY COLUMNS AT SUB-ATMOSPHERIC OUTLET PRESSURES [J].
CRAMERS, CA ;
SCHERPENZEEL, GJ ;
LECLERCQ, PA .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :207-216
[3]   Novel column heater for fast capillary gas chromatography [J].
Ehrmann, EU ;
Dharmasena, HP ;
Carney, K ;
Overton, EB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (12) :533-539
[4]   A NEW METHOD FOR PREDICTION OF BINARY GAS-PHASE DIFFUSION COEFFECIENTS [J].
FULLER, EN ;
SCHETTLE, PD ;
GIDDINGS, JC .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1966, 58 (05) :19-+
[5]   INFLUENCE OF INSTRUMENTAL CONTRIBUTIONS ON APPARENT COLUMN EFFICIENCY IN HIGH-SPEED GAS-CHROMATOGRAPHY [J].
GASPAR, G ;
ANNINO, R ;
VIDALMADJAR, C ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1512-1518
[6]  
Grant D., 1996, CAPILLARY GAS CHROMA
[7]   Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent [J].
Groves, WA ;
Zellers, ET ;
Frye, GC .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :131-143
[8]   THEORETICAL AND PRACTICAL ASPECTS OF SHORT OPEN TUBULAR COLUMNS AT SUBAMBIENT PRESSURES IN GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HAIL, ME ;
YOST, RA .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2402-2410
[9]  
INGRAHAM D, 1981, HRC-J HIGH RES CHROM, V5, P227
[10]   GAS-LIQUID PARTITION CHROMATOGRAPHY - THE SEPARATION AND MICRO-ESTIMATON OF VOLATILE FATTY ACIDS FROM FORMIC ACID TO DODECANOIC ACID [J].
JAMES, AT ;
MARTIN, AJP .
BIOCHEMICAL JOURNAL, 1952, 50 (05) :679-690