Column performance and stability for high-speed vacuum-outlet GC of volatile organic compounds using atmospheric pressure air as carrier gas

被引:27
作者
Grall, AJ [1 ]
Sacks, RD [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac990573y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of lightweight, portable GC instrumentation is handicapped by the need for compressed carrier gas to drive the separation. The use of air as carrier gas eliminates the need for compressed gas tanks. If a vacuum pump is used to pull carrier gas and injected samples through the column, atmospheric pressure air can be used as carrier gas. Vacuum outlet operation also improves performance for high-speed separations by reducing detector dead time and by shifting optimal carrier gas velocity to higher values. Under vacuum outlet conditions using atmospheric pressure air as carrier gas, a 6-m-long, 0.25-mm-i.d. capillary column can generate similar to 12 500 theoretical plates, and a 12-m-long column can generate similar to 44 000 plates but with a 3-4-fold increase in separation time. The principal issues in column selection for highspeed GC with air as a carrier gas are efficiency and stability. Several bonded and nonbonded stationary phases were evaluated for use with air as carrier gas in the analysis of volatile organic compounds of interest in air-monitoring applications. These include dimethylpolysiloxane, 50% phenyl-50% methyl polysiloxane, 50% cycanopropylphenyl-50% methyl polysiloxane, trifluropropyl polysiloxane, poly(ethylene glycol), and dicyanoallyl polysiloxane (nonbonded). The dimethyl polysiloxane and the trifluropropyl polysiloxane columns showed good efficiency and no significant deterioration after 5 days of continuous operation with air as carrier gas. The 50% phenyl-50% methyl polysiloxane and the 50% cycanopropylphenyl-50% methyl polysiloxane columns showed poorer efficiency, and the poly(ethylene glycol) and dicyanoallyl polysiloxane columns showed excessive deterioration in air.
引用
收藏
页码:5199 / 5205
页数:7
相关论文
共 24 条
[11]  
KLEMP M, 1994, J ENV SCI TECHNOL, V28, pA369
[12]   CRYOFOCUSING INLET WITH REVERSE FLOW SAMPLE COLLECTION FOR GAS-CHROMATOGRAPHY [J].
KLEMP, MA ;
AKARD, ML ;
SACKS, RD .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2516-2521
[13]  
LECLERCQ PA, 1985, J HIGH RES CHROMATOG, V8, P764, DOI 10.1002/jhrc.1240081112
[14]   MINIMUM ANALYSIS TIME IN CAPILLARY GAS-CHROMATOGRAPHY - VACUUM-OUTLET VERSUS ATMOSPHERIC-OUTLET COLUMN OPERATION [J].
LECLERCQ, PA ;
CRAMERS, CA .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :269-272
[15]   INCREASED SPEED OF ANALYSIS IN DIRECTLY COUPLED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY SYSTEMS .2. ADVANTAGES OF VACUUM OUTLET OPERATION OF THICK-FILM CAPILLARY COLUMNS [J].
LECLERCQ, PA ;
SCHERPENZEEL, GJ ;
VERMEER, EAA ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY, 1982, 241 (01) :61-71
[16]  
LEE G, 1989, AM LAB, V21, P110
[17]  
Liu Z, 1989, J MICROCOLUMN SEP, V1, P249
[18]  
OVERTON EB, 1997, FIELD ANAL CHEM TECH, V1, P87
[19]  
PARK J, IN PRESS AM IND HYG
[20]   LOW-PRESSURE GAS-CHROMATOGRAPHY WITH SPLIT INJECTION AND PHOTOIONIZATION DETECTION [J].
PUIG, L ;
SACKS, RD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (04) :158-164