The use of TEPC for reference dosimetry

被引:28
作者
Lindborg, L [1 ]
Kyllönen, JE
Beck, P
Bottollier-Depois, JF
Gerdung, S
Grillmaier, RE
Schrewe, U
机构
[1] Swedish Radiat Protect Inst, S-17116 Stockholm, Sweden
[2] Austrian Res Ctr Seibersdorf, A-2444 Seibersdorf, Austria
[3] Inst Protect & Surete Nucl, F-92265 Fontenay Aux Roses, France
[4] Univ Saarlandes, D-66125 Saarbrucken, Germany
[5] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
D O I
10.1093/oxfordjournals.rpd.a032959
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The radiation fields on board aircraft are quite complex and cover an energy range that is unusual in ordinary radiation protection work. Usually dosemeters measure only one radiation quality and the mixture found on board makes measurements complicated. There is also some doubt when it comes to the best choice of quantity for this application and no radiation standards exist for this kind of radiation field. For those reasons there is a need to find a standard measurement procedure that could serve as a reference for other, maybe simpler, measurements or for calculations of route doses. The only direct reading dosemeter that both measures the absorbed dose to tissue and the radiation quality (in terms of lineal energy) is the tissue-equivalent proportional counter (TEPC). The instrument was originally developed for scientific purposes and is still used as such. The detector consists of a gas filled cavity surrounded by a few mm thick wall. Both wall and gas consists of tissue-like material. The measurement principles are explained. Results observed with TEPC instruments are demonstrated. A preliminary collection of data reported by different groups from measurements on board aircraft will be shown. The results agree within +/-20 %. The conclusion is that TEPC instruments have the capacity of serving as reference instruments.
引用
收藏
页码:285 / 288
页数:4
相关论文
共 10 条
[1]   Energy response of tissue-eouivalent proportional counter for neutrons above 20 MeV [J].
Alexeev, AG ;
Kosako, T ;
Kharlampiev, SA .
RADIATION PROTECTION DOSIMETRY, 1998, 78 (02) :113-120
[2]  
[Anonymous], 1991, 1990 recommendations of the international commission on radiological protection ICRP publication 60
[3]  
*EUR COMM, 1996, 199601 EUR EUR COMM
[4]  
*EUROCAE, ED14C EUROCAE
[5]  
International Commission of Radiation Units and Measurements (ICRU), 1983, 36 ICRU
[6]  
KUNZ A, 1990, NUCL INSTRUM METH A, V299, P669
[7]  
KYLLONEN JE, 1997, SPECIAL PUBLICATION, V204
[8]  
LIM T, 1997, SPIE, V2867
[9]  
LINDBORG L, 1995, RADIAT PROT DOSIM, V61, P119
[10]  
TOMOV BT, 1996, ADV SPACE RES, V18